Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214524 DEA: 07304504 EFIS: 0714000067
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-57-R0.0/R4.5
Work Description: CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location Description: LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, CA 92821
Resident Engineer: Martin Sandoval Structure Rep.: Avtar Bains
DIME Sample ID: 2024-05-11-15
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2024
The quantity of what the sample constitutes: 3 beams
A brief description of the sample: PCC Rapid set beams
From where was the sample collected: Job Site
Laboratory sample identification: 24-0955
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A
The concrete mix design number: CTS-65-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-05-11-15-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 07/11/2024
Date Tested: 05/14/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of specimens
|
3
|
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
|
Fracture occurred at a capped section
|
No
|
|
Is a beam dimensional correction factor used?
|
Yes
|
|
Age of specimen
|
3 days
|
|
Modulus of rupture
|
790 psi
|
|
Modulus of rupture average
|
770 psi
|
|
Modulus of rupture 2
|
770 psi
|
|
Modulus of rupture 3
|
760 psi
|