Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04264724 Cty MRN Rte 101 PM R20.8/27.1 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Fabio La Serna |
Date Reported: |
07/25/2024 |
|
|
Address: |
TL Number: |
|
||
|
City: |
||||
|
Project Name: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
||||
|
Prime Contractor: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO) |
||||
|
Sample Taken Date: |
06/27/2024 |
Mix Design: |
SL4201CG |
|
|
Contractor: Unknown |
Location : MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
|||
|
Structure unique identifier: |
||||
|
Structure name: RW10 footing |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
| Temperature |
|---|
| 76 |
DIME Test ID: 2024-06-27-72-1
Certified By: Josh Velono
ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
| Slump |
|---|
| 3.5 |
DIME Test ID: 2024-06-27-72-2
Certified By: Josh Velono
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.01 | 12.63 | 81837 | 6480.0 | 1 |
| 2 | 4.02 | 12.69 | 68589 | 5404.0 | 1 |
| 3 | 4.01 | 12.63 | 64518 | 5109 | 1 |
DIME Test ID: 2024-06-27-72-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5660
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing