Sample Record for 2024-07-09-13
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994816 DEA: 010E11U4 EFIS: 0123000069
QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-1-31.1/31.6
Work Description: STRUCTURAL CONC BRIDGE, TEMP BRIDGE AND BAR REINFORCING STEEL.
Location Description: MENDOCINO COUNTY NEAR ELK FROM 0.2 MILE SOUTH OF ELK CREEK BRIDGE TO 0.2 MILE NORTH OF ELK CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 1324 S. State Street, Ukiah, CA 95482
Resident Engineer: Mojtaba Mosallai Structure Rep.: Mostafa Bayoumi
Sample Information
DIME Sample ID: 2024-07-09-13
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2024
The quantity of what the sample constitutes: 125
A brief description of the sample: Acrow part AB971L
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Acrow Bridge
Material Information
Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): AB971L
Washer Mfg. Lot Number(s): AB971L
Bolt Specification: ASTM A325
Bolt Length(s): 2.75
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: ASTM A325 HDG
Diameter/Size: 7/8”
Bolt Mfg. Lot Number: AB971L
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 8
DIME Test ID: 2024-07-09-13-11
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/02/2024
Date Tested: 07/26/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | | 1A | | | 75310 | | Proof Load | |
| |
|
UTM
|
450kip
|
|
Temperature
|
72 f
|
Test 2 of 8
DIME Test ID: 2024-07-09-13-12
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/02/2024
Date Tested: 07/26/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | AB971L | 0.8750 | 65697 | 292.23 | 10.00 | Wedge Tensile | aauvinen |
| |
|
UTM
|
450kip
|
|
Temperature
|
no data
|
Test 3 of 8
DIME Test ID: 2024-07-09-13-13
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/02/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
AB971L
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.875 in
|
|
Bolt Length
|
2.75 in
|
|
Gage Type
|
Pass
|
Test 4 of 8
DIME Test ID: 2024-07-09-13-14
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/02/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
AB971L
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
DH U
|
|
Size
|
0.875 in
|
|
Gage Type
|
Pass
|
Test 5 of 8
DIME Test ID: 2024-07-09-13-15
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/02/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
AB971L
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 LE USA
|
|
Size
|
0.875 in
|
|
Bolt Length
|
2.75 in
|
|
Measurement Average
|
4.28 mils
|
Test 6 of 8
DIME Test ID: 2024-07-09-13-16
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/02/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
AB971L
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
DH U
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.71 mils
|
Test 7 of 8
DIME Test ID: 2024-07-09-13-17
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/02/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
AB971L
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
TSI F436
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.53 mils
|
Test 8 of 8
DIME Test ID: 2024-07-09-13-18
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/02/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
AB971L
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
TSI F436
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
40.7
|
|
Spacing
|
Ok
|
Tests Assigned to this Sample
| DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
| 2024-07-09-13-1 | ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | Proof Load | |
| 2024-07-09-13-2 | ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | Proof Load | |
| 2024-07-09-13-3 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-4 | ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-5 | ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-6 | ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-7 | ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-8 | ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-9 | ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
| 2024-07-09-13-10 | ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating) | 07/09/2024 | Not scheduled | Nikhil Moon | CT HQ - Vallejo Field Laboratory | | |
108451108452108453108454108455108456108457108458108459108460