Print Report | Back to Sample Detail

Sample Record for 2024-04-21-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994328 DEA: 081H0604 EFIS: 0816000130 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-34.3/45.1
Work Description: FIBER OPTIC CABLE SYSTEMS, RHMA, HMA, AND MINOR CONCRETE.
Location Description: RIVERSIDE COUNTY IN AND NEAR HEMET FROM WINCHESTER ROAD TO FAIRVIEW AVENUE
Contractor Name: GRIFFITH COMPANY
Contractor Address: Unknown
Resident Engineer: Omar Sanchez Structure Rep.: Arnel Vega

Sample Information

DIME Sample ID: 2024-04-21-17
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/25/2024
The quantity of what the sample constitutes: 20 B
A brief description of the sample: 3/4" HMA A
From where was the sample collected: Manufacturer
Laboratory sample identification: 0190A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA - Perris

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 105927
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 4

DIME Test ID: 2024-04-21-17-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/05/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7329 grams
Mass of oven-dry sample in air for Sample 1 2554.6 grams
Mass of container filled with the sample and water for Sample 1 8871 grams
Temperature of Water 25 °F
Specific Gravity for Sample 1 2.523
Theoretical maximum density at 25°C (77°F) 2516 kg/m^3

Test 2 of 4

DIME Test ID: 2024-04-21-17-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/05/2024
Date Tested: 04/30/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3 %
Percent Air Voids 2 2.7 %
Percent Air Voids 3 2.7 %
Average Percent Air Voids 2.8 %

Test 3 of 4

DIME Test ID: 2024-04-21-17-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/05/2024
Date Tested: 04/30/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.447
Bulk Specific Gravity 2 2.455
Bulk Specific Gravity 3 2.456
Average Bulk Specific Gravity 2.453

Test 4 of 4

DIME Test ID: 2024-04-21-17-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/05/2024
Date Tested: 05/02/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2150 g
Corrected Asphalt Binder Content 5.04 %
Mass Loss 114.1 g
Correction Factor (Percent by mass of HMA Specimen) 0.2 %
Moisture Content no data0 %
Temperature Compensation Factor 0.07 %
Test Temperature 538 C