Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994600 DEA: 081N1704 EFIS: 0822000107
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R108.0/R115.0
Work Description: RHMA, HIGH DENSITY POLYURETHANE INJECTION & COLD PLANE AC PAVEMENT.
Location Description: SAN BERNARDINO COUNTY NEAR BARSTOW FROM 0.6 MILE NORTH OF CLYDE V. KANE REST AREA TO 0.3 MILE SOUTH OF BIRD DITCH BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Thanh Pham Structure Rep.: Unknown
DIME Sample ID: 2024-04-22-126
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/22/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/24/2024
The quantity of what the sample constitutes: 27 Boxes
A brief description of the sample: 3/4" RHMA G
From where was the sample collected: Manufacturer
Laboratory sample identification: 0188G-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond-Victorville
DIME Test ID: 2024-04-22-126-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/05/2024
Date Tested: 04/27/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7352.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2564.1 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8864.7 grams
|
|
Temperature of Water
|
25 °F
|
|
Specific Gravity for Sample 1
|
2.439
|
|
Theoretical maximum density at 25°C (77°F)
|
2432 kg/m^3
|
DIME Test ID: 2024-04-22-126-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/05/2024
Date Tested: 04/28/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.6 %
|
|
Percent Air Voids 2
|
3.7 %
|
|
Percent Air Voids 3
|
3.8 %
|
|
Average Percent Air Voids
|
3.7 %
|
DIME Test ID: 2024-04-22-126-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/05/2024
Date Tested: 04/28/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.35
|
|
Bulk Specific Gravity 2
|
2.348
|
|
Bulk Specific Gravity 3
|
2.347
|
|
Average Bulk Specific Gravity
|
2.348
|
DIME Test ID: 2024-04-22-126-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/05/2024
Date Tested: 04/27/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2110 g
|
|
Corrected Asphalt Binder Content
|
7 %
|
|
Mass Loss
|
153.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
0.17 %
|
|
Temperature Compensation Factor
|
0.11 %
|
|
Test Temperature
|
538 C
|