Print Report | Back to Sample Detail

Sample Record for 2024-07-02-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214135 DEA: 09213404 EFIS: 0900000030 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-29.9/41.8
Work Description: ROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location Description: INYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEPE, AZ. 85284
Resident Engineer: Kris Raber Structure Rep.: Sheila Reyes

Sample Information

DIME Sample ID: 2024-07-02-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 07/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/02/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" CF & RAP
From where was the sample collected: Source
Laboratory sample identification: CF-R164
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fisher Sand & Gravel Olancha

Material Information

Source Identification (SMARA, name of Pit or Job Site): 00-00-0000
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Sample Device at Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2024-07-02-26-1
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
Data has not been verified.

Test 2 of 3

DIME Test ID: 2024-07-02-26-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/08/2024
Date Tested: 07/02/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: CF-R164 Coldfeed
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 92.4 %
Cumulative percent passing the 1/2 in. sieve 75 %
Cumulative percent passing the 3/8 in. sieve 64.1 %
Cumulative percent passing the #4 sieve 34.6 %
Cumulative percent passing the #8 sieve 23.9 %
Cumulative percent passing the #16 sieve 18 %
Cumulative percent passing the #30 sieve 13.3 %
Cumulative percent passing the #50 sieve 9.2 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 3.9 %

Test 3 of 3

DIME Test ID: 2024-07-02-26-3
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 07/08/2024
Date Tested: 07/08/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: CF-R164 RAP
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) 0.2 %
Aggregate correction factor for the 1/2 in. sieve (% passing) -5.1 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -5.1 %
Aggregate correction factor for the #4 sieve (% passing) -6.5 %
Aggregate correction factor for the #8 sieve (% passing) -3 %
Aggregate correction factor for the #16 sieve (% passing) -2.4 %
Aggregate correction factor for the #30 sieve (% passing) -2.4 %
Aggregate correction factor for the #50 sieve (% passing) -2.7 %
Aggregate correction factor for the #100 sieve (% passing) -2.5 %
Aggregate correction factor for the #200 sieve (% passing) -2.1 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 84 %
Cumulative percent passing the 3/8 in. sieve 75 %
Cumulative percent passing the #4 sieve 56 %
Cumulative percent passing the #8 sieve 46 %
Cumulative percent passing the #16 sieve 35 %
Cumulative percent passing the #30 sieve 27 %
Cumulative percent passing the #50 sieve 19 %
Cumulative percent passing the #100 sieve 12 %
Cumulative percent passing the #200 sieve 7.1 %