Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993153 DEA: 120H0474 EFIS: 1212000053
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-241-27.8/38.0
Work Description: PLACE HMA AND PERFORATED PLASTIC PIPE UNDERDRAIN.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF ROUTE 133 TO 0.5 MILE SOUTH OF ROUTE 91
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Mohamad Yacoub Structure Rep.: Unknown
DIME Sample ID: 2024-04-15-96
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2024
The quantity of what the sample constitutes: 18 BOXES OF HMA
A brief description of the sample: 3/4" HMA
From where was the sample collected: Manufacturer
Laboratory sample identification: 0181A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials
DIME Test ID: 2024-04-15-96-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/05/2024
Date Tested: 04/20/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7328.4 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2558.1 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8868.7 grams
|
|
Temperature of Water
|
25 °F
|
|
Specific Gravity for Sample 1
|
2.513
|
|
Theoretical maximum density at 25°C (77°F)
|
2506 kg/m^3
|
DIME Test ID: 2024-04-15-96-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/05/2024
Date Tested: 04/21/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.6 %
|
|
Percent Air Voids 2
|
3.4 %
|
|
Percent Air Voids 3
|
3.6 %
|
|
Average Percent Air Voids
|
3.5 %
|
DIME Test ID: 2024-04-15-96-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/05/2024
Date Tested: 04/21/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.423
|
|
Bulk Specific Gravity 2
|
2.428
|
|
Bulk Specific Gravity 3
|
2.423
|
|
Average Bulk Specific Gravity
|
2.425
|
DIME Test ID: 2024-04-15-96-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/05/2024
Date Tested: 04/20/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2145 g
|
|
Corrected Asphalt Binder Content
|
4.45 %
|
|
Mass Loss
|
112.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.66 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|