Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994297 DEA: 07336804 EFIS: 0717000014
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-118-R4.5/R9.1
Work Description: PLACE CONCRETE AND INSTALL RAILINGS.
Location Description: THE CITY AND COUNTY OF LOS ANGELES FROM 0.1 MILE WEST OF TAMPA AVENUE TO WOODLEY AVENUE
Contractor Name: MARTINEZ LANDSCAPE CO. INC
Contractor Address: 12357 SAN FERNANDO ROAD, SYLMAR CA 91342
Resident Engineer: EFRAIM CHAVEZ Structure Rep.: Adriana Pimienta
DIME Sample ID: 2024-06-25-86
TL Number from the TL Form: 062524
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 06/25/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2024
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 6X12 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-163
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Associated Ready Mix
The concrete mix design number: 556300
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: 58324070
Concrete batch plant: Associated Ready Mix
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-06-25-86-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/02/2024
Date Tested: 07/02/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
6.02 in
|
|
Average diameter of cylinder 2
|
6.02 in
|
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
|
Compressive strength (to nearest 10 psi)
|
2080 psi
|
|
Maximum load on cylinder 1
|
58485 lb
|
|
Maximum load on cylinder 2
|
59783 lb
|
|
Compressive strength of cylinder 1
|
2055.0 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
2100.6 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2024-06-25-86-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/09/2024
Date Tested: 07/09/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
6.02 in
|
|
Average diameter of cylinder 2
|
6.01 in
|
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
|
Compressive strength (to nearest 10 psi)
|
2620 psi
|
|
Maximum load on cylinder 1
|
77187 lb
|
|
Maximum load on cylinder 2
|
71556 lb
|
|
Compressive strength of cylinder 1
|
2712.1 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
2522.2 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
14 days
|
|
Age of specimen in hours
|
no data0 hours
|
DIME Test ID: 2024-06-25-86-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/23/2024
Date Tested: 07/23/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
6.01 in
|
|
Average diameter of cylinder 2
|
6.01 in
|
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
|
Compressive strength (to nearest 10 psi)
|
3580 psi
|
|
Maximum load on cylinder 1
|
99801 lb
|
|
Maximum load on cylinder 2
|
103112 lb
|
|
Compressive strength of cylinder 1
|
3517.8 psi
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Compressive strength of cylinder 2
|
3634.5 psi
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|