Project ID: 994534 DEA: 010H1604 EFIS: 0117000117
QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-101-R33.7/R43.2
Work Description: REPLACE AC SURFACING, PLACE HMA-A, RHMA-G & CONCRETE BARRIER.
Location Description: MENDOCINO COUNTY NEAR WILLITS FROM 1.1 MILES NORTH OF WEST ROAD OVERCROSSING TO 0.6 MILE SOUTH OF HAEHL CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 715 COMSTOCK STREET, SANTA CLARA CA 95054
Resident Engineer: Steve Tisell Structure Rep.: Unknown
DIME Sample ID: 2024-06-27-40
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: High Friction Surface Treatment
Sample Taken Date: 06/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/28/2024
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / HFST RESIN
From where was the sample collected: Source
Laboratory sample identification: 000083KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-06-27-40-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 09/30/2024
Date Tested: 08/06/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-06-27-40-2
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 09/30/2024
Date Tested: 07/08/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results: ASTM D638
Other Results:
ASTM C881 Gel Time: 28 min
ASTM D1640 Cure Rate 1.5 Hours
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.487 in
|
|
Sample 1 Ultimate strength
|
3833 psi
|
|
Sample 1 Thickness
|
0.141 in
|
|
Sample 1 Area
|
0.0687 in^2
|
|
Sample 1 Ultimate Strength Actual
|
263.327 lbs
|
|
Sample 1 percent elongation
|
68.5 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.493 in
|
|
Sample 2 Thickness
|
0.136 in
|
|
Sample 2 Area
|
0.067 in^2
|
|
Sample 2 Ultimate strength
|
3044 psi
|
|
Sample 2 Ultimate Strength Actual
|
203.948 lbs
|
|
Sample 2 percent elongation
|
44.8 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.492 in
|
|
Sample 3 Thickness
|
0.141 in
|
|
Sample 3 Area
|
0.0694 in^2
|
|
Sample 3 Ultimate strength
|
3458 psi
|
|
Sample 3 Ultimate Strength Actual
|
239.985 lbs
|
|
Sample 3 percent elongation
|
59.9 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.485 in
|
|
Sample 4 Thickness
|
0.137 in
|
|
Sample 4 Area
|
0.0664 in^2
|
|
Sample 4 Ultimate strength
|
3844 psi
|
|
Sample 4 Ultimate Strength Actual
|
255.242 lbs
|
|
Sample 4 percent elongation
|
68.8 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.486 in
|
|
Sample 5 Thickness
|
0.146 in
|
|
Sample 5 Area
|
0.071 in^2
|
|
Sample 5 Ultimate strength
|
3478 psi
|
|
Sample 5 Ultimate Strength Actual
|
246.938 lbs
|
|
Sample 5 percent elongation
|
60.9 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.488 in
|
|
Sample 6 Thickness
|
0.144 in
|
|
Sample 6 Area
|
0.0703 in^2
|
|
Sample 6 Ultimate strength
|
3577 psi
|
|
Sample 6 Ultimate Strength Actual
|
251.463 lbs
|
|
Sample 6 percent elongation
|
64.3 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
3539 psi
|
|
Percent Elongation Average
|
61 %
|