Print Report | Back to Sample Detail

Sample Record for 2024-06-27-33

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994115 DEA: 010H1914 EFIS: 0117000211 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-96-27/27.4
Work Description: Project Name: Bluff Creek Wall
Location Description: HUMBOLDT COUNTY NEAR WEITCHPEC FROM 0.6 MILE TO 0.2 MILE WEST OF BLUFF CREEK ROAD
Contractor Name: Mercer-Fraser Company
Contractor Address: PO Box 1006, Eureka, CA 95502
Resident Engineer: Efren Banuelos Structure Rep.: Adlai Evans

Sample Information

DIME Sample ID: 2024-06-27-33
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/28/2024
The quantity of what the sample constitutes: 4 Boxes 180 ton
A brief description of the sample: 1/2" HMA PG 64-16
From where was the sample collected: Manufacturer
Laboratory sample identification: 24-103
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Company, Willow Creek Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-06-27-33-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/01/2024
Date Tested: 07/01/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1709.4 g
Corrected Asphalt Binder Content 5.11 %
Mass Loss 96.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.54 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C