Project Information

Project ID: 995202 DEA: 033H6104 EFIS: 0318000019 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-42.7/49.3
Work Description: RDWY EXC, HMA, JPCP, ALT PIPELINER, STEEL SOLDIER PILE, MOD LTG SYSTEM
Location Description: PLACER COUNTY ABOUT 9.4 MILES NORTH OF COLFAX FROM 0.5 MILE WEST OF MONTE VISTA OVERCROSSING TO 0.3 MILE EAST OF DRUM FOREBAY OVERCROSSING
Contractor Name: DESILVA GATES CONSTRUCTION, LLC
Contractor Address: 11555 Dublin Blvd, Dublin, CA 94568
Resident Engineer: Tad Sampson Structure Rep.: Jimmer Ross

Sample Information

DIME Sample ID: 2024-06-26-50
TL Number from the TL Form:
Sample Submitted By Organization: Rinker Materials
Sample Organization Contact: (916) 381-3910
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/26/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2024
The quantity of what the sample constitutes: Date's Production
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Rinker Materials

Material Information

The concrete mix design number: mix5
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2-13021
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Besser Hopper
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2024-06-26-50-1
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/27/2024
Date Tested: 06/27/2024
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4060 psi
Maximum load on cylinder 1 3980 lb
Maximum load on cylinder 2 3980 lb
Maximum load on cylinder 3 4210 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 1 days
Age of specimen in hours 0 hours

Test 2 of 6

DIME Test ID: 2024-06-26-50-2
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 06/27/2024
Date Tested: 06/26/2024
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Precast Maximum Curing Temperature 121.5 °F

Test 3 of 6

DIME Test ID: 2024-06-26-50-3
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/25/2024
Date Tested: 07/03/2024
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 6650 psi
Maximum load on cylinder 1 84420 lb
Maximum load on cylinder 2 82675 lb
Maximum load on cylinder 3 83485 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours 0 hours

Test 4 of 6

DIME Test ID: 2024-06-26-50-4
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/27/2024
Date Tested: 07/24/2024
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 8050 psi
Maximum load on cylinder 1 97800 lb
Maximum load on cylinder 2 101595 lb
Maximum load on cylinder 3 104140 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours 0 hours

Test 5 of 6

DIME Test ID: 2024-06-26-50-5
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/27/2024
Date Tested: 07/24/2024
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 8050 psi
Maximum load on cylinder 1 97800 lb
Maximum load on cylinder 2 101595 lb
Maximum load on cylinder 3 104140 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours 0 hours

Test 6 of 6

DIME Test ID: 2024-06-26-50-6
Test Method: ASTM C1064-12: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 07/27/2024
Date Tested: 06/26/2024
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 84 F