Sample Record for 2024-06-14-53
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994859 DEA: 021H5904 EFIS: 0216000025
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-96-43.5,57.0
Work Description: REPLACE CULVERTS WITH BRIDGES, STREAMBED RESTORATION, & LANDSCAPING.
Location Description: SISKIYOU COUNTY AT AND NEAR HAPPY CAMP AT 0.8 MILE WEST OF GORDON\\'S FERRY ROAD AND AT PORTUGUESE CREEK
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 17400 CLEAR CREEK ROAD, REDDING, CA 96001
Resident Engineer: Nicholas Riddle Structure Rep.: Nicolas Jimenez
Sample Information
DIME Sample ID: 2024-06-14-53
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2024
The quantity of what the sample constitutes: 3 - 4x8 cylinders
A brief description of the sample: 3 - 4x8 cylinders
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kie-Con Antioch
Material Information
The concrete mix design number: 02-1H5904
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 02-1H5904
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: at the source
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2024-06-14-53-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/26/2024
Date Tested: 07/12/2024
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: COMPRESSIVE STRENGTH IS MORE THAN 7000 PSI, COMPRESSIVE TESTING MACHINE MAX LOAD IS 7000 PSI
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
no data
|
|
Apparent mass of submerged cylinder 1
|
1 lb
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.02 in
|
|
Average diameter of cylinder 3
|
4.02 in
|
|
Cross sectional area of cylinder 1
|
12.622 in^2
|
|
Cross sectional area of cylinder 2
|
12.685 in^2
|
|
Cross sectional area of cylinder 3
|
12.685 in^2
|
|
Compressive strength (to nearest 10 psi)
|
7000 psi
|
|
Maximum load on cylinder 1
|
87967 lb
|
|
Maximum load on cylinder 2
|
87967 lb
|
|
Maximum load on cylinder 3
|
87967 lb
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
NO FRACTURE PATTERN
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|