Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995155 DEA: 040Q8104 EFIS: 0418000158
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-121-16.0
Work Description: REPAIR PAVEMENT, REPLACE DRAINAGE SYSTEMS, AND REPLACE GUARDRAIL.
Location Description: NAPA COUNTY AT CIRCLE OAKS AT WOODEN VALLEY ROAD
Contractor Name: ARGONAUT CONSTRUCTORS
Contractor Address: 1236 CENTRAL AVENUE, SANTA ROSA CA 95401
Resident Engineer: Paramdeep Brar Structure Rep.: Unknown
DIME Sample ID: 2024-06-11-96
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/17/2024
The quantity of what the sample constitutes: LOT 1 SUBLOT 2
A brief description of the sample: 1/2-INCH HMA Type A and B
From where was the sample collected: Supplier
Laboratory sample identification: Con_24_436
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Vallejo Batch Plant
DIME Test ID: 2024-06-11-96-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/08/2024
Date Tested: 06/17/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Vulcan Vallejo Batch Plant
Theoretical maximum density=2.404
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples
|
1
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.411
|
Theoretical maximum density at 25°C (77°F)
|
2404 kg/m^3
|
DIME Test ID: 2024-06-11-96-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/08/2024
Date Tested: 06/17/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Vulcan Vallejo Batch Plant
LOT 1 SUBLOT 2
Test Result Compliance: does not comply
Additional Comments When Verified:
Bulk Specific Gravity
|
2.188
|
Bulk Specific Gravity 2
|
2.278
|
Average Bulk Specific Gravity
|
2.233
|
DIME Test ID: 2024-06-11-96-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/08/2024
Date Tested: 06/17/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Vulcan Vallejo Batch Plant
LOT 1 SUBLOT 2
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids
|
90.7 %
|
Percent Air Voids 2
|
94.5 %
|
Average Percent Air Voids
|
92.6 %
|