Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995155 DEA: 040Q8104 EFIS: 0418000158
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-121-16.0
Work Description: REPAIR PAVEMENT, REPLACE DRAINAGE SYSTEMS, AND REPLACE GUARDRAIL.
Location Description: NAPA COUNTY AT CIRCLE OAKS AT WOODEN VALLEY ROAD
Contractor Name: ARGONAUT CONSTRUCTORS
Contractor Address: 1236 CENTRAL AVENUE, SANTA ROSA CA 95401
Resident Engineer: Paramdeep Brar Structure Rep.: Unknown
DIME Sample ID: 2024-06-11-95
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2024
The quantity of what the sample constitutes: 2 Boxes LOT 1 SUBLOT 2
A brief description of the sample: 1/2-INCH HMA Type A and B
From where was the sample collected: Supplier
Laboratory sample identification: Con_24_429
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Vallejo Batch Plant
DIME Test ID: 2024-06-11-95-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/08/2024
Date Tested: 06/14/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: LOT 1 SUBLOT 2
Test Result Compliance: does not comply
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1699.7 g
|
|
Corrected Asphalt Binder Content
|
6.94 %
|
|
Mass Loss
|
149.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.7 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.18 %
|
|
Test Temperature
|
482 C
|