Print Report | Back to Sample Detail

Sample Record for 2024-06-21-45

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994397 DEA: 073393U4 EFIS: 0722000031 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-R11.4/R19.5
Work Description: CONSTRUCT DPPIA DEVICES AND MODIFY LIGHTING SYSTEMS.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF SLAUSON AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF VALLEY BOULEVARD UNDERCROSSING
Contractor Name: Chumo Construction
Contractor Address: 14425 Joanbridge St, Baldwin Park, CA 91706
Resident Engineer: Peter Lee Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-06-21-45
TL Number from the TL Form: 018930
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/25/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/8" HMA-A Dike
From where was the sample collected: Manufacturer
Laboratory sample identification: 24-157
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/8 inch
Lot number:
Sublot number:
HMA Mix Number: 109426
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-06-21-45-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/26/2024
Date Tested: 06/26/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4021 g
Mass of the specimen and specimen basket assembly prior to ignition 5602.8 g
Mass of HMA Sample prior to ignition 1581.8 g
Corrected Asphalt Binder Content 6.4 %
Mass Loss 101.2 g
Mass of aggregate remaining after ignition 1480.6 g
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C