Print Report | Back to Sample Detail

Sample Record for 2024-06-17-81

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995255 DEA: 041J9604 EFIS: 0414000403 QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-1-22.8/33.0,45.0/50.5
Work Description: COLD PLANE, RHMA, HMA, MGS, CURB RAMPS, SIDEWALKS, AND CULVERTS.
Location Description: MARIN COUNTY IN AND NEAR POINT REYES STATION FROM FIVE BROOKS TO 1.9 MILES NORTH OF CYPRESS ROAD AND IN AND NEAR TOMALES FROM 0.2 MILES SOUTH OF TOMALES TO 4.4 MILES NORTH OF TOMALES
Contractor Name: O.C. JONES & SONS, INC.
Contractor Address: Unknown
Resident Engineer: Andrew Wong Structure Rep.: Jeremy Light

Sample Information

DIME Sample ID: 2024-06-17-81
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Richmond Field Laboratory
Sample Organization Contact: (510) 231-7151
Type of Sample: Independent Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/18/2024
The quantity of what the sample constitutes: 4 boxes
A brief description of the sample: Batch -Hot Mix
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BoDean Company Santa Rosa

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 1
HMA Mix Number: 700SPW16
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 3

DIME Test ID: 2024-06-17-81-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/24/2024
Date Tested: 06/18/2024
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Boulevard,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94508
Organization Email: santiago.sequeira@dot.ca.gov
Organization Phone: (510) 385-7641
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2076.1 g
Corrected Asphalt Binder Content 5.74 %
Mass Loss 127.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.7 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 482 C

Test 2 of 3

DIME Test ID: 2024-06-17-81-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/24/2024
Date Tested: 06/17/2024
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Boulevard,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94508
Organization Email: santiago.sequeira@dot.ca.gov
Organization Phone: (510) 385-7641
General Comments for this Test: Lot 1 SL 1 Production Start up
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2025.4 g
Corrected Asphalt Binder Content 5.43 %
Mass Loss 119.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.7 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 482 C

Test 3 of 3

DIME Test ID: 2024-06-17-81-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/24/2024
Date Tested: 06/17/2024
Submitted By Organization: CT D04 - Richmond Field Laboratory
Organization Address: 3401 Regatta Boulevard,
Organization City: Richmond
Organization State: CA
Organization Zipcode: 94508
Organization Email: santiago.sequeira@dot.ca.gov
Organization Phone: (510) 385-7641
General Comments for this Test: RAP- Burn Only
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1968.5 g
Corrected Asphalt Binder Content 8.61 %
Mass Loss 158.7 g
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor 0.15 %
Test Temperature 482 C