STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 041X3204 Cty SON Rte 1 PM 38.58

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Harley Paulo

Date Reported:

07/05/2024

Address:

TL Number:

City:

Project Name: Construct soldier pile wall, repair east side slide w/ concrete canvass, reconstruct roadway, reconstruct metal beam guardrail, pavement delineation, install structural shotcrete, stain concrete/shotcrete, install cable railing, and install erosions contr

Prime Contractor: O.C. Jones & Sons Inc. (Renan Modesto)

Sample Taken Date:

06/21/2024

Mix Design:

72203043F

Contractor: Unknown

Location : Ocean Cove (North) Emergency Wall at Walsh Landing

Structure unique identifier: 20-0116

Structure name: Ocean Cove Emergency Wall

Location of Pour: Soldier Piles 11&13


The following testing has been tested in accordance with:

ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete

Temperature
75

DIME Test ID: 2024-06-21-3-3
Certified By: Lauren Lau


ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete

Slump
7

DIME Test ID: 2024-06-21-3-4
Certified By: Lauren Lau


ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

Cured in accordance with ASTM C511

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0012.57547394356.01
24.0012.57536614270.01
34.0012.575335142461

DIME Test ID: 2024-06-21-3-5
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4290
Age of specimen: 7 days
Certified By: Spencer Adams


ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

Cured in accordance with ASTM C511

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
14.0112.63597234729.04
24.0212.69584734607.04
34.0112.635359442444

DIME Test ID: 2024-06-21-3-6
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4530
Age of specimen: 14 days
Certified By: Spencer Adams



Summary of Items Observed and Conversations:

Test ID: 2024-06-21-3-3: Ambient 70F

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing