Project Information

Project ID: 995221 DEA: 024H0004 EFIS: 0218000067 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-97,161-45.0/54.1,0.0/0.8
Work Description: HOT MIX ASPHALT, PAVEMENT DELINEATION, & ELECTRICAL WORK.
Location Description: SISKIYOU COUNTY IN AND NEAR DORRIS ON ROUTE 97 FROM 0.3 MILE SOUTH OF SAMS NECK ROAD TO OREGON STATE LINE AND ON ROUTE 161 FROM ROUTE 97 TO 0.6 MILE EAST OF INDIAN TOM LAKE ROAD
Contractor Name: ROCKY MOUNTAIN CONSTRUCTION
Contractor Address: Unknown
Resident Engineer: Austin Henry Structure Rep.: Nicolas Jimenez

Sample Information

DIME Sample ID: 2024-06-13-75
TL Number from the TL Form: C858496
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 06/13/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/19/2024
The quantity of what the sample constitutes: 2 cans for chip seal/seal coats
A brief description of the sample: 2 cans
From where was the sample collected: Source
Laboratory sample identification: PG641612224KF40
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Albina - Klamath Falls, OR

Material Information

Performance Grade: PG 64-28
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Albina Asphalt (Klamath Falls Plant) - Klamath Falls OR
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2024-06-13-75-1
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/26/2024
Date Tested: 06/20/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Original
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.139 kPa
Phase Angle (δ) (for the 10 cycles) 84.0 degree
Complex Modulus (G*) (for the 10 measurements) 1.153 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 1.16 kPa

Test 2 of 5

DIME Test ID: 2024-06-13-75-2
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/26/2024
Date Tested: 06/20/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.320 kPa
Phase Angle (δ) (for the 10 cycles) 77.7 degree
Complex Modulus (G*) (for the 10 measurements) 3.187 kPa
Test Temperature (Specimen 1) 64.0 C
Dynamic Shear, G*/sin(δ) 3.26 kPa

Test 3 of 5

DIME Test ID: 2024-06-13-75-3
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 06/26/2024
Date Tested: 06/21/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 41.792 kPa
Phase Angle (δ) (for the 10 cycles) 44.4 degree
Complex Modulus (G*) (for the 10 measurements) 4158.281 kPa
Test Temperature (Specimen 1) 22.0 C
(G*) x sin(δ)= 2909 kPa

Test 4 of 5

DIME Test ID: 2024-06-13-75-4
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 06/26/2024
Date Tested: 06/21/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCT
Test Result Compliance: complies
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) 150 cm
Ductility of sample 150 cm

Test 5 of 5

DIME Test ID: 2024-06-13-75-5
Test Method: AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 06/26/2024
Date Tested: 06/24/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: BBR
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s -18.1 C
Maximum test bath temperature at 240 s -17.9 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) no data0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 no data0 mN
Deflection at time 0.0 s no data0 µm
Load at time 0.5 s no data0 mN
Deflection at time 0.5 s no data0 µm
Load at 60.0 s no data0 mN
Beam deflection 60.0 s no data0 µm
Measured Stiffness Modulus 60.0 s 187 MPa
Estimated Stiffness Modulus 60.0 s 187 MPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.302