Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994864 DEA: 050N74U4 EFIS: 0522000025
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-9.9/10.6
Work Description: SB 101 4D North San Ysidro to Olive Mill
Location Description: In Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing
Contractor Name: Craig Flowers (Granite Construction Company)
Contractor Address: PO Box 6744, Santa Barbara, CA 93160
Resident Engineer: Taylor Merlo Structure Rep.: Emiliano Berntsen
DIME Sample ID: 2024-06-11-87
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 06/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/18/2024
The quantity of what the sample constitutes: 3
A brief description of the sample: 1.5" Green Dowels
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Highway Products
Dowel Metal Heat Number: 4400029071
4400029072
4400029069
Dowel Epoxy Batch Number: CH0044EJ CH0174PC
Dowel Coating Specification: ASTM A775
Dowel Size: 1.5 in
Dowel Coating Color: Green
Dowel Manufacturer:
Dowel Coater: Simcote Inc
Release Number:
Quality Assurance Code:
Rebar Size (#):
DIME Test ID: 2024-06-11-87-1
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 06/19/2024
Date Tested: 06/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
First Bar Mean
|
9.62
|
|
Second Bar Mean
|
12.1
|
|
Lower spec. limit LSL
|
7 mils
|
|
Upper spec. limit USL
|
40 mils
|
|
Total mean value
|
10.86
|
|
Total number of values less than LSL
|
no data
|
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2024-06-11-87-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 06/19/2024
Date Tested: 06/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Total Number of Holiday
|
no data0
|
|
Total Length
|
3
|
|
Holidays Per Linear Foot of Bar
|
no data0 holiday per ft
|
|
Holiday Test Pass/Fail
|
Pass
|