Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994051 DEA: 041Q5814 EFIS: 0421000262
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0-6.5
Work Description: REHABILITATE PAVEMENT AND UPGRADE MEDIAN BARRIER [PS&E E-COPY AVAILABLE UPON REQUEST]
Location Description: SAN MATEO COUNTY FROM SAN MATEO COUNTY LINE IN EAST PALO ALTO TO WHIPPLE AVENUE IN REDWOOD CITY
Contractor Name: BAY CITIES PAVING & GRADING, INC.
Contractor Address: Unknown
Resident Engineer: Ethan Malonzo Structure Rep.: Unknown
DIME Sample ID: 2024-06-10-77
TL Number from the TL Form: C0821232
Sample Submitted By Organization: CT D04 - Hayward Field Laboratory
Sample Organization Contact: (510) 723-0168
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2024
The quantity of what the sample constitutes: 0-750 Tons
A brief description of the sample: 1/2 RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Co - Pleasanton
DIME Test ID: 2024-06-10-77-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/17/2024
Date Tested: 06/13/2024
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
2
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7334.8 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1574.7 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8256.6 grams
|
|
Mass of container filled with water 2
|
7334.8 grams
|
|
Mass of oven-dry sample in air for Sample 2
|
1579.9 grams
|
|
Mass of container filled with the sample and water for Sample 2
|
8261.5 grams
|
|
Temperature of Water
|
no data0 °F
|
|
Specific Gravity for Sample 1
|
2.412
|
|
Specific Gravity for Sample 2
|
2.419
|
|
Average Specific Gravity
|
2.415
|
|
Theoretical maximum density at 25°C (77°F)
|
2408 kg/m^3
|
DIME Test ID: 2024-06-10-77-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 06/17/2024
Date Tested: 06/13/2024
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test: Lot 1 Sublot 10
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.3
|
DIME Test ID: 2024-06-10-77-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/17/2024
Date Tested: 06/13/2024
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test: Lot 1 Sublot 10
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Fahrenheit
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3119.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4664 g
|
|
Mass of HMA Sample prior to ignition
|
1544.2 g
|
|
Corrected Asphalt Binder Content
|
7.3 %
|
|
Mass Loss
|
131.3 g
|
|
Mass of aggregate remaining after ignition
|
1412.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.01 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
5.38 F
|
DIME Test ID: 2024-06-10-77-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/17/2024
Date Tested: 06/11/2024
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test: Lot 1 Sublot 9
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3052.2 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4637.5 g
|
|
Mass of HMA Sample prior to ignition
|
1585.3 g
|
|
Corrected Asphalt Binder Content
|
7.74 %
|
|
Mass Loss
|
141.7 g
|
|
Mass of aggregate remaining after ignition
|
1443.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.01 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
538 C
|