Print Report | Back to Sample Detail

Sample Record for 2024-06-10-29

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995059 DEA: 081G6404 EFIS: 0816000046 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-395-R4.0/49.0
Work Description: REPLACE ASPHALT CONCRETE SURFACING, COLD PLANE AC PVMT AND RHMA.
Location Description: SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM ROUTE 15/395 SEPARATION TO 3.1 MILES NORTH OF ROUTE 58/395 SEPARATION
Contractor Name: SULLY-MILLER CONTRACTING COMPANY
Contractor Address: 135 S State College Blvd, Brea, Ca 92821
Resident Engineer: Shaun Loza Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-06-10-29
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2024
The quantity of what the sample constitutes: 24 BOXES OF HMA, 2 QTS OIL, 4 BAGS UNTREATED AGGS
A brief description of the sample: 3/4" HMA-A-SP R15, 1.0%LSM
From where was the sample collected: Manufacturer
Laboratory sample identification: 0286A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Diamond Materials-Victorville

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 300154 R15 LSM

Test Results

Test 1 of 4

DIME Test ID: 2024-06-10-29-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/08/2024
Date Tested: 06/12/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7328.3 grams
Mass of oven-dry sample in air for Sample 1 2563.4 grams
Mass of container filled with the sample and water for Sample 1 8867.1 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.502
Theoretical maximum density at 25°C (77°F) 2495 kg/m^3

Test 2 of 4

DIME Test ID: 2024-06-10-29-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/08/2024
Date Tested: 06/14/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.0 %
Percent Air Voids 2 3.1 %
Percent Air Voids 3 2.9 %
Percent Air Voids Average 3.0 %

Test 3 of 4

DIME Test ID: 2024-06-10-29-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/08/2024
Date Tested: 06/14/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.426
Bulk Specific Gravity 2 2.425
Bulk Specific Gravity 3 2.430
Average Bulk Specific Gravity 2.427

Test 4 of 4

DIME Test ID: 2024-06-10-29-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/08/2024
Date Tested: 06/12/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2104.0 g
Corrected Asphalt Binder Content 4.70 %
Mass Loss 110.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.41 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C