Project Information

Project ID: 995061 DEA: 081J9104 EFIS: 0818000135 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV,SBD-10,15,60,62,91,etc.-Var
Work Description: MODIFYING CMS SYSTEMS, SIGN FOUNDATION AND SIGN STRUCTURE.
Location Description: RIVERSIDE AND SAN BERNARDINO COUNTIES AT VARIOUS LOCATIONS
Contractor Name: POWELL CONSTRUCTORS, INC.
Contractor Address: Unknown
Resident Engineer: George Salloum Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-06-03-45
TL Number from the TL Form: 1067-01J
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/03/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/06/2024
The quantity of what the sample constitutes: 8
A brief description of the sample: 4X8
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NO

Material Information

The concrete mix design number: 1610974
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 31219738
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: SITE
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2024-06-03-45-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/11/2024
Date Tested: 06/10/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 4190 psi
Maximum load on cylinder 1 52290 lb
Maximum load on cylinder 2 53610 lb
Compressive strength of cylinder 1 4140.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4240.0 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test 2 of 3

DIME Test ID: 2024-06-03-45-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/17/2024
Date Tested: 06/17/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 5300 psi
Maximum load on cylinder 1 67780 lb
Maximum load on cylinder 2 65930 lb
Compressive strength of cylinder 1 5370.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 5220.0 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test 3 of 3

DIME Test ID: 2024-06-03-45-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/01/2024
Date Tested: 07/01/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Compressive strength (to nearest 10 psi) 6330 psi
Maximum load on cylinder 1 81090 lb
Maximum load on cylinder 2 78650 lb
Compressive strength of cylinder 1 6420.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 6230.0 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen no data0 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data