Print Report | Back to Sample Detail

Sample Record for 2024-06-04-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211605 DEA: 043G4444 EFIS: 0412000044 QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-5.9/7.7
Work Description: SFOBB WEST SPAN MAIN CABLE WRAP. Repair main cable and replace suspender ropes, and tower access doors.
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF SAN FRANCISCO ANCHORAGE TO 0.1 MILE SOUTH OF YERBA BUENA ANCHORAGE
Contractor Name: American Bridge Company (Wade Barie)
Contractor Address: 1000 American Bridge Way, Coraopolis, PA 15108
Resident Engineer: Daniel Guzman Structure Rep.: Sergio Gomez

Sample Information

DIME Sample ID: 2024-06-04-11
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 06/04/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/11/2024
The quantity of what the sample constitutes: 32
A brief description of the sample: 2 pieces 2" x 21.5" ASTM A354 Gr BC Heavy Hex Bolt with ASTM A563 Grade C Heavy Hex Nut Grade C
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dyson Corporation

Material Information

Rocap Number(s):
Heat Number(s): 73125691, 20916840
Nut Mfg. Lot Number(s): BVKV6
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM A354 Grade BC
Bolt Length(s): 21.5"
Nut Specification: ASTM A563 Grade C
Washer Specification: NA
Finish: Plain
Diameter/Size: 2
Bolt Mfg. Lot Number: DEJA13
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):

Test Results

Test 1 of 4

DIME Test ID: 2024-06-04-11-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 06/25/2024
Date Tested: 06/20/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1731256910.5040.211639813865021.6aauvinen
UTM 67kip
Temperature 72 f

Test 2 of 4

DIME Test ID: 2024-06-04-11-2
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 06/25/2024
Date Tested: 06/20/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
2731256910.5040.212039914103319.7aauvinen
UTM 67kip
Temperature 72 f

Test 3 of 4

DIME Test ID: 2024-06-04-11-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/25/2024
Date Tested: 06/21/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DEJA13
Finish Coating Plain
Product Markings BC
Size 2 in
Bolt Length 21.5 in
Pitch Diameter 1.845 in
Pitch Diameter 2nd 1.845 in

Test 4 of 4

DIME Test ID: 2024-06-04-11-4
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/25/2024
Date Tested: 06/21/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number BVKV6
Finish Coating Plain
Product Markings D/N
Size 2 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 28.33
Spacing Ok