Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214708 DEA: 07323904 EFIS: 0716000072
QA Service Level: 1
DIST-CO-RTE-PM: 07---
Work Description: COLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location Description: VENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
Contractor Name: C. A. Rasmussen, Inc.
Contractor Address: 28548 Livingston Avenue, Valencia, CA 91355
Resident Engineer: Alfred Ira Structure Rep.: Unknown
DIME Sample ID: 2024-05-02-71
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 05/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2024
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Saticoy
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2024-05-02-71-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 06/03/2024
Date Tested: 05/28/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
ASTM Thermometer used?
|
C
|
|
Softening Point Sample 1
|
69 C
|
|
Softening Point Sample 2
|
69 C
|
|
Bath Liquid
|
freshly boiled distilled water
|
|
Minutes Reaction
|
no data
|
DIME Test ID: 2024-05-02-71-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 06/03/2024
Date Tested: 05/29/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Determination
|
Prolonged Worked Penetration
|
|
Prolonged Worked Penetration
|
27 0.1 mm
|
DIME Test ID: 2024-05-02-71-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 06/03/2024
Date Tested: 05/29/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature
|
25 C
|
|
Ball Penetration (P1)
|
100 mm
|
|
Final Dial reading (F1)
|
65 mm
|
|
Ball Penetration (P2)
|
100 mm
|
|
Final Dial reading (F2)
|
60 mm
|
|
Ball Penetration (P3)
|
100 mm
|
|
Final Dial reading (F3)
|
58 mm
|
|
Resilience 1
|
35 %
|
|
Resilience 2
|
40 %
|
|
Resilience 3
|
42 %
|
|
Average Resilience
|
39 %
|
|
Minutes Reaction
|
no data
|