Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995260 DEA: 061G0504 EFIS: 0623000195
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0
Work Description: Routes 180, 245 Emergency Slip Out Repair
Location Description:
Contractor Name: CAL VALLEY CONSTRUCTION
Contractor Address: 5125 N. Gates Ave, Ste 102, Fresno, CA 93722
Resident Engineer: Mark Mengoni Structure Rep.: Ramandeep Guraya
DIME Sample ID: 2024-05-24-24
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Verification
Type of Material: Concrete
Sample Taken Date: 05/24/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/28/2024
The quantity of what the sample constitutes: 104.5
A brief description of the sample: PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Concrete Barrier Slab
The fabricator/manufacturer/facility name: Outback Materials, Fresno
The concrete mix design number: 72T1X39
The truck number from where the sample was collected: 111
The batch plant ticket number from where the sample was collected: 160474
Concrete batch plant: Outback Materials
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Barrier Slab at Wall 1
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-05-24-24-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/21/2024
Date Tested: 06/21/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
5730 psi
|
Maximum load on cylinder 1
|
72870 lb
|
Maximum load on cylinder 2
|
73440 lb
|
Maximum load on cylinder 3
|
69810 lb
|
Compressive strength of cylinder 1
|
5797.1 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
5842.5 psi
|
Compressive strength of cylinder 3
|
5553.7 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|