Sample Record for 2024-05-24-8
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995028 DEA: 010H4314 EFIS: 0117000214
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-299-R11.0/R11.4
Work Description: Project Name: Korbel Wall (Description of Work: CONSTRUCT RETAINING WALL, RECONSTRUCT ROADWAY, & REPLACE CULVERT)
Location Description: HUMBOLDT COUNTY ABOUT 6 MILES EAST OF BLUE LAKE FROM NORTH FORK MAD RIVER BRIDGE TO 0.4 MILE EAST OF NORTH FORK MAD RIVER BRIDGE
Contractor Name: MCCULLOUGH CONSTRUCTION INC
Contractor Address: 57 Aldergrove Road, Arcata, CA 95521
Resident Engineer: Brenda Howell Structure Rep.: Dustin Helliwell
Sample Information
DIME Sample ID: 2024-05-24-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/24/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/25/2024
The quantity of what the sample constitutes: 57 CY
A brief description of the sample: Type II/V Cement
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 12-0E0058
Structure name: Korbel Wall
The fabricator/manufacturer/facility name: Eureka Ready mix
Material Information
The concrete mix design number: E400F
The truck number from where the sample was collected: 83
The batch plant ticket number from where the sample was collected: 36027
Concrete batch plant: Arcata Eureka Ready Mix
The fabricator/manufacturer designation for the sample: Batch
A detailed description of where the material sample was collected: Concrete Truck Chute
Where the material sample would have been placed if not sampled: Waler 1
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 5
DIME Test ID: 2024-05-24-8-1
Test Method: CTM 557-July 2012: Method of Test for Temperature of Freshly Mixed Portland Cement Concrete
Verified Date: 05/24/2024
Date Tested: 05/24/2024
Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 55
Test Result Compliance: complies
Additional Comments When Verified:
|
Temperature of the freshly mixed concrete
|
73 F
|
Test 2 of 5
DIME Test ID: 2024-05-24-8-2
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 05/24/2024
Date Tested: 05/24/2024
Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test 3 of 5
DIME Test ID: 2024-05-24-8-6
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/31/2024
Date Tested: 05/31/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
3840 psi
|
|
Maximum load on cylinder 1
|
49310 lb
|
|
Maximum load on cylinder 2
|
46700 lb
|
|
Maximum load on cylinder 3
|
48760 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
7 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 4 of 5
DIME Test ID: 2024-05-24-8-7
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/02/2024
Date Tested: 06/02/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4130 psi
|
|
Maximum load on cylinder 1
|
52420 lb
|
|
Maximum load on cylinder 2
|
51780 lb
|
|
Maximum load on cylinder 3
|
51440 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
9 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 5 of 5
DIME Test ID: 2024-05-24-8-8
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/21/2024
Date Tested: 06/21/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 28 Day Break 6/21/28
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5350 psi
|
|
Maximum load on cylinder 1
|
67270 lb
|
|
Maximum load on cylinder 2
|
66570 lb
|
|
Maximum load on cylinder 3
|
67880 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
2
|
|
Type of fracture pattern of cylinder 3
|
2
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
Tests Assigned to this Sample
| DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
| 2024-05-24-8-3 | ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | 05/24/2024 | 05/31/2024 | Dustin Helliwell | CT D01 - Boyd Road Field Laboratory | | Leif Ayres |
| 2024-05-24-8-4 | ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | 05/24/2024 | 06/02/2024 | Dustin Helliwell | CT D01 - Boyd Road Field Laboratory | | Leif Ayres |
| 2024-05-24-8-5 | ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | 05/24/2024 | 06/21/2024 | Dustin Helliwell | CT D01 - Boyd Road Field Laboratory | | Leif Ayres |
104257104258104259