Print Report | Back to Sample Detail

Sample Record for 2024-05-24-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995028 DEA: 010H4314 EFIS: 0117000214 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-299-R11.0/R11.4
Work Description: Project Name: Korbel Wall (Description of Work: CONSTRUCT RETAINING WALL, RECONSTRUCT ROADWAY, & REPLACE CULVERT)
Location Description: HUMBOLDT COUNTY ABOUT 6 MILES EAST OF BLUE LAKE FROM NORTH FORK MAD RIVER BRIDGE TO 0.4 MILE EAST OF NORTH FORK MAD RIVER BRIDGE
Contractor Name: MCCULLOUGH CONSTRUCTION INC
Contractor Address: 57 Aldergrove Road, Arcata, CA 95521
Resident Engineer: Brenda Howell Structure Rep.: Dustin Helliwell

Sample Information

DIME Sample ID: 2024-05-24-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/24/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/25/2024
The quantity of what the sample constitutes: 57 CY
A brief description of the sample: Type II/V Cement
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 12-0E0058
Structure name: Korbel Wall
The fabricator/manufacturer/facility name: Eureka Ready mix

Material Information

The concrete mix design number: E400F
The truck number from where the sample was collected: 83
The batch plant ticket number from where the sample was collected: 36027
Concrete batch plant: Arcata Eureka Ready Mix
The fabricator/manufacturer designation for the sample: Batch
A detailed description of where the material sample was collected: Concrete Truck Chute
Where the material sample would have been placed if not sampled: Waler 1
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 5

DIME Test ID: 2024-05-24-8-1
Test Method: CTM 557-July 2012: Method of Test for Temperature of Freshly Mixed Portland Cement Concrete
Verified Date: 05/24/2024
Date Tested: 05/24/2024
Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 55
Test Result Compliance: complies
Additional Comments When Verified:
Temperature of the freshly mixed concrete 73 F

Test 2 of 5

DIME Test ID: 2024-05-24-8-2
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 05/24/2024
Date Tested: 05/24/2024
Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Slump 6 inch

Test 3 of 5

DIME Test ID: 2024-05-24-8-6
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/31/2024
Date Tested: 05/31/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3840 psi
Maximum load on cylinder 1 49310 lb
Maximum load on cylinder 2 46700 lb
Maximum load on cylinder 3 48760 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 4 of 5

DIME Test ID: 2024-05-24-8-7
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/02/2024
Date Tested: 06/02/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4130 psi
Maximum load on cylinder 1 52420 lb
Maximum load on cylinder 2 51780 lb
Maximum load on cylinder 3 51440 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 9 days
Age of specimen in hours no data0 hours

Test 5 of 5

DIME Test ID: 2024-05-24-8-8
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/21/2024
Date Tested: 06/21/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 28 Day Break 6/21/28
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 5350 psi
Maximum load on cylinder 1 67270 lb
Maximum load on cylinder 2 66570 lb
Maximum load on cylinder 3 67880 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-05-24-8-3ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens05/24/202405/31/2024Dustin HelliwellCT D01 - Boyd Road Field LaboratoryLeif Ayres
2024-05-24-8-4ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens05/24/202406/02/2024Dustin HelliwellCT D01 - Boyd Road Field LaboratoryLeif Ayres
2024-05-24-8-5ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens05/24/202406/21/2024Dustin HelliwellCT D01 - Boyd Road Field LaboratoryLeif Ayres