Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040A7104 Cty ALA Rte 880 PM 28.4/29.2 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Joy Cheung |
Date Reported: |
11/01/2016 |
|
Address: |
TL Number: |
194845 |
||
City: |
||||
Project Name: WIDEN ROADS, RECONSTRUCT RAMPS WITH HMA, REPLACE 2 CONC OVERCROSSINGS. |
||||
Prime Contractor: RGW Construction |
||||
Sample Taken Date: |
10/04/2016 |
Mix Design: |
D101c5r1 |
|
Contractor: Unknown |
Location : ALAMEDA COUNTY IN ALAMEDA AND OAKLAND FROM 0.2 MILE SOUTH OF 29TH AVENUE OVERCROSSING TO 0.3 MILE NORTH OF 23RD AVENUE OVERCROSSING. |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.97 | 27.99 | 185275 | 6619.3 | 2 |
2 | 5.97 | 27.99 | 181877 | 6497.9 | 1 |
DIME Test ID: 2016-10-04-4-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6560
Age of specimen: 28 days
Certified By: Bang Nguyen
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing