Print Report | Back to Sample Detail

Sample Record for 2024-05-13-86

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 44444 DEA: ASCP EFIS: ASCP QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-13-86
TL Number from the TL Form:
Sample Submitted By Organization: Centennial Asphalt
Sample Organization Contact: (801) 831-6014
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 05/13/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/13/2024
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Tank 60001
From where was the sample collected: Manufacturer
Laboratory sample identification: 1332751025
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bakerfield, CA

Material Information

Performance Grade: PG 64-16
Modified:
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Centennial Asphalt - Bakersfield CA
Multigrade: Yes
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 8

DIME Test ID: 2024-05-13-86-1
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s? Pa-s
Time of test no data
Test Temperature no data
Speed no data
Spindle size no data
Torque no data
Viscosity reading #1 (A) no data
Viscosity reading #2 (B) no data
Viscosity reading #3 (C) no data
Average viscosity 0.392 Pa-s

Test 2 of 8

DIME Test ID: 2024-05-13-86-2
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase Original binder
Phase Angle (δ) (for the 10 cycles) no data
Dynamic Shear, G*/sin(δ) 1.39 kPa

Test 3 of 8

DIME Test ID: 2024-05-13-86-3
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers? One
Average mass change -0.328 percent

Test 4 of 8

DIME Test ID: 2024-05-13-86-4
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase RTFO residue
Phase Angle (δ) (for the 10 cycles) no data
Dynamic Shear, G*/sin(δ) 4.28 kPa

Test 5 of 8

DIME Test ID: 2024-05-13-86-5
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) no data
Ductility of sample 81 cm

Test 6 of 8

DIME Test ID: 2024-05-13-86-6
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter no data
Phase Angle (δ) (for the 10 cycles) no data
(G*) x sin(δ)= 2823 kPa

Test 7 of 8

DIME Test ID: 2024-05-13-86-7
Test Method: AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Time test started no data
Flags issued by software during test no data
Correlation coefficient (R²) no data0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 no data0 mN
Deflection at time 0.0 s no data0 µm
Load at time 0.5 s no data0 mN
Deflection at time 0.5 s no data0 µm
Load at 60.0 s no data0 mN
Beam deflection 60.0 s no data0 µm
Measured Stiffness Modulus 60.0 s no data
Estimated Stiffness Modulus 60.0 s 80.1 mPa
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s no data

Test 8 of 8

DIME Test ID: 2024-05-13-86-8
Test Method: AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 05/23/2024
Date Tested: 05/23/2024
Submitted By Organization: Centennial Asphalt
Organization Address: 1201 China Grade Loop,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: george.peterson@gcinc.com
Organization Phone: (801) 831-6014
General Comments for this Test: Submitted from ASCP bulk upload.
Test Result Compliance:
Additional Comments When Verified:
Time test started no data
Flags issued by software during test no data
Correlation coefficient (R²) no data0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 no data0 mN
Deflection at time 0.0 s no data0 µm
Load at time 0.5 s no data0 mN
Deflection at time 0.5 s no data0 µm
Load at 60.0 s no data0 mN
Beam deflection 60.0 s no data0 µm
Measured Stiffness Modulus 60.0 s no data
Estimated Stiffness Modulus 60.0 s no data
Difference between stiffness moduli 60.0 s no data
Estimated m-value 60.0 s 0.316