Print Report | Back to Sample Detail

Sample Record for 2024-05-02-62

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000330 DEA: 024H0804 EFIS: 0218000075 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-96-R0/R16
Work Description: Somes Bar CAPM
Location Description: In Siskiyou County at and near Somes Bar from Humboldt County Line to 0.1 mile west of Dillon Creek Bridge
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-02-62
TL Number from the TL Form: 848872
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Preliminary
Type of Material: Soil
Sample Taken Date: 05/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/02/2024
The quantity of what the sample constitutes: 1 container for culvert recommendation C-18
A brief description of the sample: Soil for culvert recommendation, C-18
From where was the sample collected: Source
Laboratory sample identification: D79513
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: In Situ

Material Information

The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: 02-SIS-96-14.56 @ INLET
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 1

DIME Test ID: 2024-05-02-62-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 05/22/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: pH=4.92, p=12176.Ω∙cm
Test Result Compliance: not applicable
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 12175.75 Ohm-cm
Minimum soil resistivity at 15.5 12176 Ohm-cm
Minimum soil resistance of the lab measurement 11300 Ohms
Soil sample temperature 18.6 C
pH of soil 4.92