Print Report | Back to Sample Detail

Sample Record for 2024-05-21-30

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214708 DEA: 07323904 EFIS: 0716000072 QA Service Level: 1
DIST-CO-RTE-PM: 07---
Work Description: COLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location Description: VENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
Contractor Name: C. A. Rasmussen, Inc.
Contractor Address: 28548 Livingston Avenue, Valencia, CA 91355
Resident Engineer: Alfred Ira Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-21-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2024
The quantity of what the sample constitutes: 20 BOXES OF RHMA-G, 4 BAGS OF COMBINED BELTCUT
A brief description of the sample: 1/2" RHMA-G +WMA 0.50% EVO M1
From where was the sample collected: Manufacturer
Laboratory sample identification: 0258G-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Saticoy

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number: 17
Sublot number:
HMA Mix Number: 326122 SAT VLO
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 4

DIME Test ID: 2024-05-21-30-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/08/2024
Date Tested: 05/24/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7328.4 grams
Mass of oven-dry sample in air for Sample 1 1556.2 grams
Mass of container filled with the sample and water for Sample 1 8239.6 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.413
Theoretical maximum density at 25°C (77°F) 2406 kg/m^3

Test 2 of 4

DIME Test ID: 2024-05-21-30-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/08/2024
Date Tested: 05/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.3 %
Percent Air Voids 2 3.4 %
Percent Air Voids 3 3.6 %
Average Percent Air Voids 3.4 %

Test 3 of 4

DIME Test ID: 2024-05-21-30-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/08/2024
Date Tested: 05/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.334
Bulk Specific Gravity 2 2.331
Bulk Specific Gravity 3 2.325
Average Bulk Specific Gravity 2.33

Test 4 of 4

DIME Test ID: 2024-05-21-30-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/08/2024
Date Tested: 05/24/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1686 g
Corrected Asphalt Binder Content 7.54 %
Mass Loss 130.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.03 %
Moisture Content no data0 %
Temperature Compensation Factor 0.18 %
Test Temperature 538 C