Print Report | Back to Sample Detail

Sample Record for 2024-05-13-78

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for storing JMF sample data
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-13-78
TL Number from the TL Form:
Sample Submitted By Organization: Martin Marietta
Sample Organization Contact: (619) 455-3295
Type of Sample: Quality Control
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 05/13/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/13/2024
The quantity of what the sample constitutes: 50lbs of RAP
A brief description of the sample: RAP
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta - Santee

Material Information

RAP Source: Martin Marietta - Lakeside
Aggregate Size:
Aggregate Source:
RAP Stockpile:
Stockpile Size (tons):
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test

DIME Test ID: 2024-05-13-78-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/03/2024
Date Tested: 05/13/2024
Submitted By Organization: Martin Marietta
Organization Address: 4211 Ponderosa Avenue, Suite C,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92124
Organization Email: andrew.suarez@martinmarietta.com
Organization Phone: (619) 455-3295
General Comments for this Test: Submitted from JMF - Andrew Suarez
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? no data
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.8 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test

DIME Test ID: 2024-05-13-78-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 06/03/2024
Date Tested: 05/13/2024
Submitted By Organization: Martin Marietta
Organization Address: 4211 Ponderosa Avenue, Suite C,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92124
Organization Email: andrew.suarez@martinmarietta.com
Organization Phone: (619) 455-3295
General Comments for this Test: Submitted from JMF - Andrew Suarez
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve no data
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99 %
Cumulative percent passing the 3/8 in. sieve 88 %
Cumulative percent passing the #4 sieve 64 %
Cumulative percent passing the #8 sieve 47 %
Cumulative percent passing the #16 sieve 35 %
Cumulative percent passing the #30 sieve 27 %
Cumulative percent passing the #50 sieve 18 %
Cumulative percent passing the #100 sieve 12 %
Cumulative percent passing the #200 sieve 8 %