Print Report | Back to Sample Detail

Sample Record for 2024-05-21-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214135 DEA: 09213404 EFIS: 0900000030 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-29.9/41.8
Work Description: ROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location Description: INYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEPE, AZ. 85284
Resident Engineer: Kris Raber Structure Rep.: Sheila Reyes

Sample Information

DIME Sample ID: 2024-05-21-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/21/2024
The quantity of what the sample constitutes: 4000/10000 tons
A brief description of the sample: HMA-R86
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fisher Sand & Gravel Olancha plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 86
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 5

DIME Test ID: 2024-05-21-2-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/30/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R86
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7310.5 grams
Mass of oven-dry sample in air for Sample 1 2119.4 grams
Mass of container filled with the sample and water for Sample 1 8586.6 grams
Temperature of Water 77.5 °F
Specific Gravity for Sample 1 2.513
Theoretical maximum density at 25°C (77°F) 156.4 lb/ft^3

Test 2 of 5

DIME Test ID: 2024-05-21-2-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/30/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R86
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4273.2 g
Mass of the specimen and specimen basket assembly prior to ignition 6490.8 g
Mass of HMA Sample prior to ignition 2217.6 g
Corrected Asphalt Binder Content 4.21 %
Mass Loss 98.9 g
Mass of aggregate remaining after ignition 2118.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.25 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 3 of 5

DIME Test ID: 2024-05-21-2-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/30/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R86
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity 2.427
Bulk Specific Gravity 2 2.419
Bulk Specific Gravity 3 2.427
Average Bulk Specific Gravity 2.424

Test 4 of 5

DIME Test ID: 2024-05-21-2-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/30/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R86
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.4 %
Percent Air Voids 2 3.7 %
Percent Air Voids 3 3.4 %
Average Percent Air Voids 3.5 %

Test 5 of 5

DIME Test ID: 2024-05-21-2-6
Test Method: AASHTO T166-16: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Saturated Surface-Dry Specimens (Method A)
Verified Date: 05/30/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-R86
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 4
Bulk Specific Gravity 1 2.35
Bulk Specific Gravity 2 2.341
Bulk Specific Gravity 3 2.336
Bulk Specific Gravity 4 2.337
Percent of water absorbed by volume 1 1.63 %
Percent of water absorbed by volume 2 1.74 %
Percent of water absorbed by volume 3 1.86 %
Percent of water absorbed by volume 4 1.56 %
Average Bulk Specific Gravity 2.341

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-05-21-2-5AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)05/22/2024Not scheduledDerek CarringtonCT D09 - Bishop Field LaboratoryDerek Carrington