Print Report | Back to Sample Detail

Sample Record for 2024-05-15-59

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994311 DEA: 080R1704 EFIS: 0812000028 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R25.0/R50.0
Work Description: CONSTRUCT CSP, CSPA, SSPPA, STR CONC HW, IB, BFM, RSP, & MGS.
Location Description: SAN BERNARDINO COUNTY AT NEWBERRY SPRINGS AND LUDLOW FROM 1.6 MILES EAST OF FORT CADY ROAD OVERCROSSING TO CRUCERO ROAD UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Thanh Pham Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-15-59
TL Number from the TL Form: 1060-515
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2024
The quantity of what the sample constitutes: 3
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 1060-515
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertson

Material Information

The concrete mix design number: SM450P48
The truck number from where the sample was collected: NOT PROVIDED
The batch plant ticket number from where the sample was collected: 2326
Concrete batch plant:
The fabricator/manufacturer designation for the sample: 572369
A detailed description of where the material sample was collected: 08 SBD 40 R25-R50 I40 HECTOR RD
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-05-15-59-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Cured in accordance with ASTM C511
Verified Date: 05/22/2024
Date Tested: 05/22/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 27.99 in^2
Cross sectional area of cylinder 2 27.99 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Compressive strength (to nearest 10 psi) 3150 psi
Average diameter of cylinder 1 5.97 in
Average diameter of cylinder 2 5.97 in
Compressive strength of cylinder 1 3173.3 psi
Compressive strength of cylinder 2 3120.2 psi
Maximum load on cylinder 1 88820 lb
Maximum load on cylinder 2 87335 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days

Test 2 of 2

DIME Test ID: 2024-05-15-59-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap
Cured in accordance with ASTM C511
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
Data has not been verified.