Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-05-20-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Authorization
Type of Material: Cementitious
Sample Taken Date: 05/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/20/2024
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Blended cement (PLC)
From where was the sample collected: Source
Laboratory sample identification: CM24N408
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pan Pacific Cemindo IL(9)
DIME Test ID: 2024-05-20-10-1
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 07/17/2024
Date Tested: 06/20/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 day
Test Result Compliance:
Additional Comments When Verified:
|
Will control cubes be used per ASTM C311?
|
no
|
|
Age of specimen
|
3 days
|
|
The amount of flow
|
110.00 %
|
|
The amount of water used
|
48.4 %
|
|
Compressive strength of 1st specimen
|
2990 psi
|
|
Compressive strength of 2nd specimen
|
3059 psi
|
|
Compressive strength of 3rd specimen
|
2905 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
2980 psi
|
DIME Test ID: 2024-05-20-10-2
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 07/17/2024
Date Tested: 06/24/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: Specimen 3 was eliminated from the average for being outside allowable limits per ASTM C109
Test Result Compliance:
Additional Comments When Verified:
|
Will control cubes be used per ASTM C311?
|
no
|
|
Age of specimen
|
7 days
|
|
The amount of flow
|
110.00 %
|
|
The amount of water used
|
48.4 %
|
|
Compressive strength of 1st specimen
|
4295 psi
|
|
Compressive strength of 2nd specimen
|
4289 psi
|
|
Compressive strength of 3rd specimen
|
3831 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
4290 psi
|
DIME Test ID: 2024-05-20-10-3
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 07/17/2024
Date Tested: 07/15/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day
Test Result Compliance:
Additional Comments When Verified:
|
Will control cubes be used per ASTM C311?
|
no
|
|
Age of specimen
|
28 days
|
|
The amount of flow
|
110.00 %
|
|
The amount of water used
|
48.4 %
|
|
Compressive strength of 1st specimen
|
5271 psi
|
|
Compressive strength of 2nd specimen
|
5105 psi
|
|
Compressive strength of 3rd specimen
|
5378 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
5250 psi
|
DIME Test ID: 2024-05-20-10-4
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 07/17/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Specific gravity
|
3.117
|
|
Water Content
|
232
|
|
The amount of flow (In percent)
|
90 %
|
|
The amount of water used (In percent)
|
66.29 %
|
|
Net Weight of Sample
|
833.8 grams
|
|
Air Content
|
8 %
|
DIME Test ID: 2024-05-20-10-5
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 07/17/2024
Date Tested: 05/21/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Mass of Water
|
162 g
|
|
Mass of Dry Cement
|
650 g
|
|
Water required for normal consistency
|
25.00 %
|
DIME Test ID: 2024-05-20-10-7
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 07/17/2024
Date Tested: 05/21/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Type of Water Used
|
Type IV grade reagent water
|
|
Initial time of setting
|
145 min
|
|
Final time of setting
|
no data
|
DIME Test ID: 2024-05-20-10-6
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 07/17/2024
Date Tested: 05/21/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Density of hydraulic cement
|
3.117 g/cm^3
|
DIME Test ID: 2024-05-20-10-8
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 07/17/2024
Date Tested: 05/23/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Method Used
|
Test Method A
|
|
Test Time
|
87 seconds
|
|
Fineness
|
3715 cm^2/g
|
DIME Test ID: 2024-05-20-10-9
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 07/17/2024
Date Tested: 05/23/2024
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Corrected residue, % (Rc)
|
4.9 %
|
|
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325)
|
95.1 %
|