Sample Record for 2024-05-20-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994267 DEA: 07326204 EFIS: 0716000113
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-39-17.8
Work Description: CONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location Description: LOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
Contractor Name: FEC Future Contractors & Engineers, Inc
Contractor Address: 184 Technology Dr., Ste 2, Irvine, CA 92618
Resident Engineer: Joe Doughly Structure Rep.: Hadi Moradi
Sample Information
DIME Sample ID: 2024-05-20-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2024
The quantity of what the sample constitutes: 10 bolts
A brief description of the sample: ASTM F3125/A325 7/8" X 6" Heavy Hex Bolt Assembly
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt Inc.
Material Information
Rocap Number(s): 253512A-A
Heat Number(s): Bolt- 748698
Nut- 8000006661
Washer- 42350330
Nut Mfg. Lot Number(s): 456888A
Washer Mfg. Lot Number(s): 0224-113
Bolt Specification: ASTM A325/ F3125
Bolt Length(s): 6"
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: ASTM A153- Hot Dip Galvanized
Diameter/Size: 7/8
Bolt Mfg. Lot Number: 253512A
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 7
DIME Test ID: 2024-05-20-3-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 06/03/2024
Date Tested: 05/28/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
|
Number of Bolt Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | | 1A | 253512A | 0.8750 | 68486 | 304.64 | 10.00 | Wedge Tensile | aauvinen |
| |
|
UTM
|
450kip
|
|
Temperature
|
no data
|
Test 2 of 7
DIME Test ID: 2024-05-20-3-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 06/03/2024
Date Tested: 05/28/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
1
|
| Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | | 1A | | | 74929 | | Proof Load | |
| |
|
UTM
|
450kip
|
|
Temperature
|
72 f
|
Test 3 of 7
DIME Test ID: 2024-05-20-3-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
253512A
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 N
|
|
Size
|
0.875 in
|
|
Bolt Length
|
6 in
|
|
Pitch Diameter
|
.805 in
|
|
Pitch Diameter 2nd
|
.805 in
|
Test 4 of 7
DIME Test ID: 2024-05-20-3-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
253512A
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
A325 N
|
|
Size
|
0.875 in
|
|
Bolt Length
|
6 in
|
|
Measurement Average
|
3.95 mils
|
Test 5 of 7
DIME Test ID: 2024-05-20-3-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
456888A
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
DH N
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.23 mils
|
Test 6 of 7
DIME Test ID: 2024-05-20-3-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
0224-113
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
TSI F436
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.47 mils
|
Test 7 of 7
DIME Test ID: 2024-05-20-3-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
0224-113
|
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
|
Product Markings
|
TSI F436
|
|
Size
|
0.875 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
39.7
|
|
Spacing
|
Ok
|