Print Report | Back to Sample Detail

Sample Record for 2024-05-20-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994267 DEA: 07326204 EFIS: 0716000113 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-39-17.8
Work Description: CONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location Description: LOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
Contractor Name: FEC Future Contractors & Engineers, Inc
Contractor Address: 184 Technology Dr., Ste 2, Irvine, CA 92618
Resident Engineer: Joe Doughly Structure Rep.: Hadi Moradi

Sample Information

DIME Sample ID: 2024-05-20-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2024
The quantity of what the sample constitutes: 10 bolts
A brief description of the sample: ASTM F3125/A325 7/8" X 6" Heavy Hex Bolt Assembly
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt Inc.

Material Information

Rocap Number(s): 253512A-A
Heat Number(s): Bolt- 748698 Nut- 8000006661 Washer- 42350330
Nut Mfg. Lot Number(s): 456888A
Washer Mfg. Lot Number(s): 0224-113
Bolt Specification: ASTM A325/ F3125
Bolt Length(s): 6"
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: ASTM A153- Hot Dip Galvanized
Diameter/Size: 7/8
Bolt Mfg. Lot Number: 253512A
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):

Test Results

Test 1 of 7

DIME Test ID: 2024-05-20-3-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 06/03/2024
Date Tested: 05/28/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
1A253512A0.875068486304.6410.00Wedge Tensileaauvinen
UTM 450kip
Temperature no data

Test 2 of 7

DIME Test ID: 2024-05-20-3-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 06/03/2024
Date Tested: 05/28/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1A74929Proof Load
UTM 450kip
Temperature 72 f

Test 3 of 7

DIME Test ID: 2024-05-20-3-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 253512A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size 0.875 in
Bolt Length 6 in
Pitch Diameter .805 in
Pitch Diameter 2nd .805 in

Test 4 of 7

DIME Test ID: 2024-05-20-3-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 253512A
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 N
Size 0.875 in
Bolt Length 6 in
Measurement Average 3.95 mils

Test 5 of 7

DIME Test ID: 2024-05-20-3-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 456888A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Bolt Length no data in
Measurement Average 3.23 mils

Test 6 of 7

DIME Test ID: 2024-05-20-3-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0224-113
Finish Coating ASTM F2329 - Hot Dip
Product Markings TSI F436
Size 0.875 in
Bolt Length no data in
Measurement Average 2.47 mils

Test 7 of 7

DIME Test ID: 2024-05-20-3-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/03/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0224-113
Finish Coating ASTM F2329 - Hot Dip
Product Markings TSI F436
Size 0.875 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 39.7
Spacing Ok