Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994730 DEA: 040Y1904 EFIS: 0422000255
QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-37-R0.0/R7.4
Work Description: COLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G.
Location Description: SOLANO COUNTY IN AND NEAR VALLEJO FROM SONOMA COUNTY LINE TO NAPA RIVER BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-04-27-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/08/2024
The quantity of what the sample constitutes: LOT 1 SUBLOT 9
A brief description of the sample: 1/2-INCH RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification: Con_24_239
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Vallejo Drier Drum Plant
DIME Test ID: 2024-04-27-25-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/24/2024
Date Tested: 05/08/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Theoretical maximum density=2.336
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Specific Gravity for Sample 1
|
2.343
|
|
Theoretical maximum density at 25°C (77°F)
|
2336 kg/m^3
|
DIME Test ID: 2024-04-27-25-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/24/2024
Date Tested: 05/08/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: LOT 1 SUBLOT 9
Vulcan Vallejo Drier Drum Plant
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.233
|
|
Bulk Specific Gravity 2
|
2.24
|
|
Average Bulk Specific Gravity
|
2.237
|