Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994578 DEA: 070W2504 EFIS: 0721000211
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60-R4.4/R29.8
Work Description: FURNISH POLYESTER CONCRETE OVERLAY.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM ATLANTIC BOULEVARD UNDERCROSSING TO TOWNE AVENUE UNDERCROSSING
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION INC.
Contractor Address: 16351 CONSTRUCTION CIRCLE, IRVINE CA 92606
Resident Engineer: JOE DOUGHLY Structure Rep.: Unknown
DIME Sample ID: 2024-05-08-58
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 05/08/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/09/2024
The quantity of what the sample constitutes: 10 Tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000064KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-05-08-58-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 06/18/2024
Date Tested: 06/17/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-05-08-58-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 06/18/2024
Date Tested: 06/17/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2024-05-08-58-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 06/18/2024
Date Tested: 05/15/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.486 in
|
Sample 1 Ultimate strength
|
3071 psi
|
Sample 1 Thickness
|
0.259 in
|
Sample 1 Area
|
0.1259 in^2
|
Sample 1 Ultimate Strength Actual
|
386.639 lbs
|
Sample 1 percent elongation
|
59.5 %
|
Sample 1 Time
|
no data0 MM:SS
|
Sample 2 Width
|
0.486 in
|
Sample 2 Thickness
|
0.257 in
|
Sample 2 Area
|
0.1249 in^2
|
Sample 2 Ultimate strength
|
3486 psi
|
Sample 2 Ultimate Strength Actual
|
435.401 lbs
|
Sample 2 percent elongation
|
72.9 %
|
Sample 2 Time
|
no data0 MM:SS
|
Sample 3 Width
|
0.486 in
|
Sample 3 Thickness
|
0.263 in
|
Sample 3 Area
|
0.1278 in^2
|
Sample 3 Ultimate strength
|
3093 psi
|
Sample 3 Ultimate Strength Actual
|
395.285 lbs
|
Sample 3 percent elongation
|
53.3 %
|
Sample 3 Time
|
no data0 MM:SS
|
Sample 4 Width
|
0.486 in
|
Sample 4 Thickness
|
0.256 in
|
Sample 4 Area
|
0.1244 in^2
|
Sample 4 Ultimate strength
|
3224 psi
|
Sample 4 Ultimate Strength Actual
|
401.066 lbs
|
Sample 4 percent elongation
|
66.5 %
|
Sample 4 Time
|
no data0 MM:SS
|
Sample 5 Width
|
0.486 in
|
Sample 5 Thickness
|
0.265 in
|
Sample 5 Area
|
0.1288 in^2
|
Sample 5 Ultimate strength
|
3196 psi
|
Sample 5 Ultimate Strength Actual
|
411.644 lbs
|
Sample 5 percent elongation
|
66.7 %
|
Sample 5 Time
|
no data0 MM:SS
|
Sample 6 Width
|
0.486 in
|
Sample 6 Thickness
|
0.271 in
|
Sample 6 Area
|
0.1317 in^2
|
Sample 6 Ultimate strength
|
3254 psi
|
Sample 6 Ultimate Strength Actual
|
428.552 lbs
|
Sample 6 percent elongation
|
68.7 %
|
Sample 6 Time
|
no data0 MM:SS
|
Ultimate Strength Average
|
3221 psi
|
Percent Elongation Average
|
65 %
|
DIME Test ID: 2024-05-08-58-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 06/18/2024
Date Tested: 06/17/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
46.2
|
DIME Test ID: 2024-05-08-58-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 06/18/2024
Date Tested: 05/17/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1581.24 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
790.62 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1175.27 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
587.635 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1314.87 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
657.437 psi
|
DIME Test ID: 2024-05-08-58-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 06/18/2024
Date Tested: 05/16/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
78 f
|
Tare weight
|
no data
|
Initial weight
|
100.04 grams
|
Weight at 5 minutes
|
99.993 grams
|
Weight at 10 minutes
|
99.946 grams
|
Weight at 15 minutes
|
99.904 grams
|
Weight at 20 minutes
|
99.85 grams
|
Weight at 25 minutes
|
99.808 grams
|
Weight at 30 minutes
|
99.761 grams
|
Final weight
|
99.76 grams
|
Total weight loss
|
0.28 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
15.052 grams/m^2
|