Project Information

Project ID: 994730 DEA: 040Y1904 EFIS: 0422000255 QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-37-R0.0/R7.4
Work Description: COLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G.
Location Description: SOLANO COUNTY IN AND NEAR VALLEJO FROM SONOMA COUNTY LINE TO NAPA RIVER BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-12-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/12/2024
The quantity of what the sample constitutes: 1545Grams
A brief description of the sample: 1/2-INCH RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification: Con_24_287
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Vallejo Drier Drum plant

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 16
HMA Mix Number: 326128D

Test Results

Test 1 of 1

DIME Test ID: 2024-05-12-21-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/15/2024
Date Tested: 05/12/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: LOT 1 SUBLOT 16 Vulcan Vallejo Drier Drum Plant
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1545.0 g
Corrected Asphalt Binder Content 7.55 %
Mass Loss 138.7 g
Correction Factor (Percent by mass of HMA Specimen) 1.23 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.19 %
Test Temperature 538 C