Print Report | Back to Sample Detail

Sample Record for 2024-05-14-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-14-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2024
The quantity of what the sample constitutes: 1399
A brief description of the sample: A449 All Thread Rod
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales, Inc

Material Information

Rocap Number(s): na
Heat Number(s): 8000014870
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s): na
Bolt Specification: A449
Bolt Length(s): 12"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 5/8"
Bolt Mfg. Lot Number: W86411
Rocap Test Requirement(s): na
Lubricant Requirements(s): na

Test Results

Test 1 of 8

DIME Test ID: 2024-05-14-6-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 06/04/2024
Date Tested: 05/29/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1AUNC 5/8 0.2263129013913844812152327464A449 Wedge Tensile
UTM 400kip
Temperature 72

Test 2 of 8

DIME Test ID: 2024-05-14-6-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 06/04/2024
Date Tested: 05/29/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A449 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1BUNC 5/8 0.2263138413913886412217627612A449 Wedge Tensile
UTM 400kip
Temperature 72

Test 3 of 8

DIME Test ID: 2024-05-14-6-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/04/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 8000014870
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 0.625 in
Bolt Length 12 in
Pitch Diameter .576 in
Pitch Diameter 2nd .576 in

Test 4 of 8

DIME Test ID: 2024-05-14-6-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/04/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 8000014870
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 0.625 in
Bolt Length 12 in
Pitch Diameter .575 in
Pitch Diameter 2nd .575 in

Test 5 of 8

DIME Test ID: 2024-05-14-6-5
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 06/04/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 8000014870
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 0.625 in
Bolt Length 12 in
Pitch Diameter .570 in
Pitch Diameter 2nd .570 in

Test 6 of 8

DIME Test ID: 2024-05-14-6-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/04/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 8000014870
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 0.625 in
Bolt Length 12 in
Measurement Average 4.78 mils

Test 7 of 8

DIME Test ID: 2024-05-14-6-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/04/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 8000014870
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 0.625 in
Bolt Length 12 in
Measurement Average 5.58 mils

Test 8 of 8

DIME Test ID: 2024-05-14-6-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/04/2024
Date Tested: 05/31/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 8000014870
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings no data
Size 0.625 in
Bolt Length 12 in
Measurement Average 4.24 mils