Print Report | Back to Sample Detail

Sample Record for 2024-04-29-58

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993336 DEA: 07328804 EFIS: 0716000183 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-R54.4/R54.8
Work Description: BUILDING WORK.
Location Description: LOS ANGELES COUNTY IN SANTA CLARITA FROM NORTHBOUND OFF-RAMP TO NORTHBOUND ON-RAMP CASTAIC WEIGH STATION
Contractor Name: Kanaan Construction Inc.
Contractor Address: 230 S Irwindale Ave, Azusa, CA 91702
Resident Engineer: Mohammad Zakir Khan Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-04-29-58
TL Number from the TL Form: 042924
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 04/29/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/30/2024
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 6X12 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-067
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: National Ready Mix Concrete Company

Material Information

The concrete mix design number: SC590B38
The truck number from where the sample was collected: 2129
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: National Ready Mix Concrete
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-04-29-58-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/13/2024
Date Tested: 05/13/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 3540 psi
Maximum load on cylinder 1 101358 lb
Maximum load on cylinder 2 98786 lb
Compressive strength of cylinder 1 3572.7 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3505.5 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 14 days
Age of specimen in hours 0 hours