Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215348 DEA: 060U4204 EFIS: 0616000004
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-99-R4.9/11.6
Work Description: CONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location Description: FRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Rd. Suite 200, Westlake Village CA 91361
Resident Engineer: Chris Wilfong Structure Rep.: Unknown
DIME Sample ID: 2024-05-09-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/09/2024
The quantity of what the sample constitutes: 750-1500 Tons
A brief description of the sample: 3/4 HMA Type A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Sanger
DIME Test ID: 2024-05-09-25-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/10/2024
Date Tested: 05/10/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
3932.1 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5997.6 g
|
Mass of HMA Sample prior to ignition
|
2065.5 g
|
Corrected Asphalt Binder Content
|
4.91 %
|
Mass Loss
|
104.7 g
|
Mass of aggregate remaining after ignition
|
1960.8 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.16 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.00 %
|
Test Temperature
|
538 C
|