Print Report | Back to Sample Detail

Sample Record for 2024-05-09-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-09-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/20/2024
The quantity of what the sample constitutes: 2000
A brief description of the sample: F436 Flat Washer
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales, Inc.

Material Information

Rocap Number(s): na
Heat Number(s): 235967
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): E6048
Bolt Specification: na
Bolt Length(s): na
Nut Specification: na
Washer Specification: F436
Finish: HDG
Diameter/Size: 1-1/4
Bolt Mfg. Lot Number: na
Rocap Test Requirement(s): na
Lubricant Requirements(s): na
Washer Inner Diameter(s):

Test Results

Test 1 of 6

DIME Test ID: 2024-05-09-5-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/28/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6048
Finish Coating ASTM F2329 - Hot Dip
Product Markings P F436
Size 1.25 in
Bolt Length no data in
Measurement Average 2.52 mils

Test 2 of 6

DIME Test ID: 2024-05-09-5-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/28/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6048
Finish Coating ASTM F2329 - Hot Dip
Product Markings P F436
Size 1.25 in
Bolt Length no data in
Measurement Average 2.38 mils

Test 3 of 6

DIME Test ID: 2024-05-09-5-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 06/28/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6048
Finish Coating ASTM F2329 - Hot Dip
Product Markings P F436
Size 1.25 in
Bolt Length no data in
Measurement Average 2.18 mils

Test 4 of 6

DIME Test ID: 2024-05-09-5-4
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/28/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6048
Finish Coating ASTM F2329 - Hot Dip
Product Markings P F436
Size 1.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 30.05
Spacing Ok

Test 5 of 6

DIME Test ID: 2024-05-09-5-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/28/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6048
Finish Coating ASTM F2329 - Hot Dip
Product Markings P F436
Size 1.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 31.15
Spacing Ok

Test 6 of 6

DIME Test ID: 2024-05-09-5-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 06/28/2024
Date Tested: 06/25/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number E6048
Finish Coating ASTM F2329 - Hot Dip
Product Markings P F436
Size 1.25 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 30.7
Spacing Ok