Project Information

Project ID: 995498 DEA: 072XL104 EFIS: 0724000158 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-14.23
Work Description: LA-10, Construct temporary structural shoring - Column Casings Repair Work
Location Description: I-10 at Olympic Blvd
Contractor Name: SECURITY PAVING COMPANY INC
Contractor Address: 13170 TELEFAIR AVE, SYLMAR, CA 91342
Resident Engineer: Sepand Minovi Structure Rep.: Suh Kwangsuk

Sample Information

DIME Sample ID: 2024-04-11-74
TL Number from the TL Form: 04-11-66
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 04/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/30/2024
The quantity of what the sample constitutes: 130 CY
A brief description of the sample: 4X8 PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-066
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Security Paving company

Material Information

The concrete mix design number: 45ESCC
The truck number from where the sample was collected: 3823
The batch plant ticket number from where the sample was collected: 1922219
Concrete batch plant: Security Paving Company
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-04-11-74-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/09/2024
Date Tested: 05/09/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.01 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.02 in
Cross sectional area of cylinder 1 12.63 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.69 in^2
Compressive strength (to nearest 10 psi) 7960 psi
Maximum load on cylinder 1 101090 lb
Maximum load on cylinder 2 100602 lb
Maximum load on cylinder 3 100529 lb
Compressive strength of cylinder 1 8004.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 7965.3 psi
Compressive strength of cylinder 3 7921.9 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours