Project ID: 994116 DEA: 010J4104 EFIS: 0119000025
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-299-30.7/33.4
Work Description: Project Name: HUM-299 Curve Improvement
Location Description: HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE
Contractor Name: McCullough Construction Inc.
Contractor Address: 57 Alder Grove Road, Arcata, CA 95521
Resident Engineer: Ethan Retherford Structure Rep.: Laura Cangas
DIME Sample ID: 2024-04-22-70
TL Number from the TL Form:
Sample Submitted By Organization: SHN Engineers & Geologists, Incorporated
Sample Organization Contact: (707) 441-8855
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/22/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/23/2024
The quantity of what the sample constitutes: 30 CY
A brief description of the sample: E67538WRF
From where was the sample collected: Job Site
Laboratory sample identification: C9152
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Eureka Ready Mix
The concrete mix design number: E67538WRF
The truck number from where the sample was collected: 94
The batch plant ticket number from where the sample was collected: 35429
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete sample from wheelbarrow
Where the material sample would have been placed if not sampled: Barrier Wall
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-04-22-70-1
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 12/31/2024
Date Tested: 04/22/2024
Submitted By Organization: SHN Engineers & Geologists, Incorporated
Organization Address: 812 West Wabash Avenue,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: dgonzales@shn-engr.com
Organization Phone: (707) 441-8855
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-04-22-70-2
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 05/08/2024
Date Tested: 04/22/2024
Submitted By Organization: SHN Engineers & Geologists, Incorporated
Organization Address: 812 West Wabash Avenue,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: dgonzales@shn-engr.com
Organization Phone: (707) 441-8855
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-04-22-70-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 05/08/2024
Date Tested: 04/22/2024
Submitted By Organization: SHN Engineers & Geologists, Incorporated
Organization Address: 812 West Wabash Avenue,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: dgonzales@shn-engr.com
Organization Phone: (707) 441-8855
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-04-22-70-4
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 05/08/2024
Date Tested: 04/22/2024
Submitted By Organization: SHN Engineers & Geologists, Incorporated
Organization Address: 812 West Wabash Avenue,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: dgonzales@shn-engr.com
Organization Phone: (707) 441-8855
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Identification of concrete represented by the sample
|
E67538WRF
|
|
Volume of the measure
|
0.249 ft^3
|
|
Density of concrete
|
136.3 lb/ft^3
|
|
Yield of concrete
|
no data
|
|
Relative yield of the batch
|
no data
|
|
Cement content
|
no data
|
|
Air content
|
7 %
|
DIME Test ID: 2024-04-22-70-5
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/08/2024
Date Tested: 04/28/2024
Submitted By Organization: SHN Engineers & Geologists, Incorporated
Organization Address: 812 West Wabash Avenue,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: dgonzales@shn-engr.com
Organization Phone: (707) 441-8855
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
2480 psi
|
|
Maximum load on cylinder 1
|
31420 lb
|
|
Maximum load on cylinder 2
|
30740 lb
|
|
Maximum load on cylinder 3
|
31140 lb
|
|
Type of fracture pattern of cylinder 1
|
2
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
6
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
6 days
|
|
Age of specimen in hours
|
no data0 hours
|