Print Report | Back to Sample Detail

Sample Record for 2024-05-05-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994327 DEA: 081G4704 EFIS: 0816000001 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-3.1/53.5
Work Description: STRUCTURAL CONC BR, CONC SLAB, HMA (TYPE A), ALT CRASH CUSHION SYSTEM.
Location Description: RIVERSIDE COUNTY NEAR LAKE ELSINORE AT MORRILL CANYON BRIDGE AND NEAR HEMET AT STRAWBERRY CREEK BRIDGE.
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 26320 LESTER CIRCLE;, CORONA CA 92883
Resident Engineer: Mike A Bergevin Structure Rep.: Arnel Vega

Sample Information

DIME Sample ID: 2024-05-05-8
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/05/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/07/2024
The quantity of what the sample constitutes: 2 BOXES OF HMA
A brief description of the sample: 3/4" HMA-A-SP R15
From where was the sample collected: Manufacturer
Laboratory sample identification: 0228A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 105927
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-05-05-8-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/13/2024
Date Tested: 05/10/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2119.7 g
Corrected Asphalt Binder Content 4.54 %
Mass Loss 99.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.02 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C