Sample Record for 2024-05-02-16
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994820 DEA: 060V1104 EFIS: 0616000208
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,KIN-5,41,198-Var
Work Description: STRATFORD KINGS RIVER BRIDGE REPLACEMENT.
Location Description: FRESNO AND KINGS COUNTIES AT VARIOUS LOCATIONS
Contractor Name: M.C.M. Construction, INC. (Richard McCall)
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Din Dadawalla Structure Rep.: Martin Garcia
Sample Information
DIME Sample ID: 2024-05-02-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/03/2024
The quantity of what the sample constitutes: 12- 4X8 Cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 45-0110
Structure name:
The fabricator/manufacturer/facility name: MCM Construction
Material Information
The concrete mix design number: 93T3G50
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: 158846
Concrete batch plant: Outback
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Pier Caps 7&6
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 3
DIME Test ID: 2024-05-02-16-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/07/2024
Date Tested: 05/07/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
4.02 in
|
Average diameter of cylinder 2
|
4.02 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.69 in^2
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
4860 psi
|
Maximum load on cylinder 1
|
62330 lb
|
Maximum load on cylinder 2
|
62250 lb
|
Maximum load on cylinder 3
|
59710 lb
|
Compressive strength of cylinder 1
|
4911.7 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
4905.4 psi
|
Compressive strength of cylinder 3
|
4750.2 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
5 days
|
Age of specimen in hours
|
0 hours
|
Test 2 of 3
DIME Test ID: 2024-05-02-16-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/11/2024
Date Tested: 05/11/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.01 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
Compressive strength (to nearest 10 psi)
|
5740 psi
|
Maximum load on cylinder 1
|
74190 lb
|
Maximum load on cylinder 2
|
71270 lb
|
Maximum load on cylinder 3
|
71520 lb
|
Compressive strength of cylinder 1
|
5902.1 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
5669.8 psi
|
Compressive strength of cylinder 3
|
5662.7 psi
|
Type of fracture pattern of cylinder 2
|
5
|
Type of fracture pattern of cylinder 3
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
9 days
|
Age of specimen in hours
|
0 hours
|
Test 3 of 3
DIME Test ID: 2024-05-02-16-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/30/2024
Date Tested: 05/30/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
4.02 in
|
Average diameter of cylinder 2
|
4.02 in
|
Average diameter of cylinder 3
|
4.02 in
|
Cross sectional area of cylinder 1
|
12.69 in^2
|
Cross sectional area of cylinder 2
|
12.69 in^2
|
Cross sectional area of cylinder 3
|
12.69 in^2
|
Compressive strength (to nearest 10 psi)
|
7240 psi
|
Maximum load on cylinder 1
|
90540 lb
|
Maximum load on cylinder 2
|
89850 lb
|
Maximum load on cylinder 3
|
95200 lb
|
Compressive strength of cylinder 1
|
7134.8 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
7080.4 psi
|
Compressive strength of cylinder 3
|
7502 psi
|
Type of fracture pattern of cylinder 2
|
5
|
Type of fracture pattern of cylinder 3
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|