Print Report | Back to Sample Detail

Sample Record for 2024-04-23-57

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994593 DEA: 081M1804 EFIS: 0821000087 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10,74,79,86,111,243-Var
Work Description: POLYESTER CONCRETE AND HOT MIX ASPHALT OVERLAY.
Location Description: RIVERSIDE COUNTY AT VARIOUS LOCATIONS
Contractor Name: TRUESDELL CORPORATION OF CALIFORNIA, INC.
Contractor Address: Unknown
Resident Engineer: Md Rahman Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-04-23-57
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/30/2024
The quantity of what the sample constitutes: 3 BOXES OF HMA, 2 QTS OIL
A brief description of the sample: 3 HMA-A R24 0.25% EVO/
From where was the sample collected: Manufacturer
Laboratory sample identification: 0207A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta -Coachella

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 43417195
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-04-23-57-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/06/2024
Date Tested: 05/03/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2111 g
Corrected Asphalt Binder Content 4.78 %
Mass Loss 110.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.33 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C