Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994574 DEA: 050C7334 EFIS: 0518000116
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-10.5/13.4
Work Description: CONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location Description: SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 580 West Beach Street, Watsonville, CA 95076
Resident Engineer: Fernando Dos Santos Structure Rep.: Luis Melendez
DIME Sample ID: 2024-04-16-49
TL Number from the TL Form:
Sample Submitted By Organization: Construction Testing Services
Sample Organization Contact: (925) 351-6905
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 04/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/16/2024
The quantity of what the sample constitutes: 16 CY
A brief description of the sample: 4000 PSI Concrete - Abutment #3 - pile #4
From where was the sample collected: Job Site
Laboratory sample identification: 273556
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Coast Concrete
The concrete mix design number: 087722
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2424
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: from chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-04-16-49-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap
Verified Date: 05/01/2024
Date Tested: 04/23/2024
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
4
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
12.25 in^2
|
Cross sectional area of cylinder 2
|
12.25 in^2
|
Cross sectional area of cylinder 3
|
12.25 in^2
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Cross sectional area of cylinder 4
|
12.25 in^2
|
Average diameter of cylinder 1
|
4.00 in
|
Compressive strength (to nearest 10 psi)
|
3820 psi
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Average diameter of cylinder 4
|
4.00 in
|
Maximum load on cylinder 1
|
48010 lb
|
Maximum load on cylinder 2
|
48010 lb
|
Maximum load on cylinder 3
|
48010 lb
|
Maximum load on cylinder 4
|
48010 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
3
|
Type of fracture pattern of cylinder 4
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Age of specimen
|
7 days
|
DIME Test ID: 2024-04-16-49-2
Test Method: CTM 556-June 2010: Method of Test for Slump of Fresh Portland Cement Concrete
Verified Date: 05/01/2024
Date Tested: 04/23/2024
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-04-16-49-3
Test Method: ASTM C173-10b: Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method
Verified Date: 05/01/2024
Date Tested: 04/23/2024
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2024-04-16-49-4
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 05/01/2024
Date Tested: 04/23/2024
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample
|
4000 PSI Concrete
|
Volume of the measure
|
0.249 ft^3
|
Density of concrete
|
147.9 lb/ft^3
|
Yield of concrete
|
no data
|
Relative yield of the batch
|
no data
|
Cement content
|
no data
|
Air content
|
no data
|