Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040K5204 Cty SON Rte 12 PM 11.0/T17.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Cody Van Beek |
Date Reported: |
06/25/2024 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: Overlay with RHMA, replace guardrails, approach slabs and signs. |
||||
Prime Contractor: FBD VANGUARD CONSTRUCTION, INC. (TOM SWISHER) |
||||
Sample Taken Date: |
04/20/2024 |
Mix Design: |
he4x12bm |
|
Contractor: Unknown |
Location : Construction on State Highway in Sonoma County from Llano Road to Farmers Lane. |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.00 | 12.57 | 77800 | 6191.0 | 1 |
2 | 4.01 | 12.63 | 77432 | 6131.0 | 1 |
3 | 4.01 | 12.63 | 67391 | 5336 | 1 |
DIME Test ID: 2024-04-20-1-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5890
Age of specimen: 30 days
Certified By: Spencer Adams
ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Temperature |
---|
66 |
DIME Test ID: 2024-04-20-1-3
Certified By: Lauren Lau
*Subject to final inspection by the Resident Engineer. |