Print Report | Back to Sample Detail

Sample Record for 2024-04-11-62

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994962 DEA: 07357304 EFIS: 0719000062 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-6.6/13.1
Work Description: REPLACE CONCRETE SLABS AND MEDIAN BARRIER,
Location Description: LOS ANGELES COUNTY IN SANTA FE SPRINGS, DOWNEY AND CITY OF COMMERCE FROM 0.2 MILE SOUTH OF ROUTE 5/605 SEPARATION TO 0.1 MILE NORT
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Martin Oregel Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-04-11-62
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 04/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/11/2024
The quantity of what the sample constitutes: 2 Bags Of Combined Agg., 1 Bag Rap
A brief description of the sample: JMF 3/8" HMA-A-SP R15 PG64-10
From where was the sample collected: Manufacturer
Laboratory sample identification: 0171A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona Quarry/ SJR

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-33-0005
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Belt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number: 109726
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-04-11-62-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory
2024-04-11-62-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates04/22/2024Not scheduledRonica BhuyianCT D08 - Fontana Southern Regional Laboratory